Pull the stripping blades (12) out.
•
Clean the centering chucks (13) (Fig. 9).
Do not mix up
the centralizers (13)!
•
Mount new stripping blades together with the centralizers.
Make sure the centralizers lever (14) fits into the recesses
(15) of the centralizers (Fig. 8).
•
Slightly tighten the set screws (10). The stripping blades
(12) should still be
slightly
movable with minimal play
(Fig. 10).
•
Push both stripping blades completely outwards of the cen-
ter (Fig. 10).
•
Plug in the mains cable and turn on the machine.
The stripping blades are centered in the
Test
mode.
Fig. 8. Centering guide lever
Fig. 9. Remove stripping blades
Fig. 10. Push both stripping
blades