23
EN
5
Press the [SETTING] dial
The set value is determined.
6
Repeat Steps 2 to 5 to perform settings
7
Press and hold the [SETTING] dial
The settings are saved, and it returns to screw fastening
mode.
The following settings are available.
LCD display
Details
Set value
Default
Reference
1) CH-CHG
Operations channel switching
method
S-AUTO / C-AUTO / INPUT
S-AUTO
p. 25
2) CH
Setting target channel
CH1 / CH2 / CH3 / CH4
-
p. 26
3) FSTN-TYPE
Screw fastening type
SOFT / HARD
SOFT
p. 26
4) TORQUE
Torque
1 to 100%
10
p. 28
5) SPEED
Speed
SOFT: 600 to 1000min
-1
HARD: 100 to 1000min
-1
600
p. 28
6) SOFT-START
Soft start level
Lv1 to 9
1
p. 28
7) FSTN-T
Fastening timer
(Setting enabled only when
No.3 has been set to “HARD”)
0.00 to 9.99s
0.00
p. 28
8) COUNT UP-BZ
Count-up buzzer sound
OFF / 1 to 10
CH1: 1
CH2: 2
CH3: 3
CH4: 4
p. 30
9) FSTN-NG-BZ
Fastening NG buzzer sound
OFF / 1 to 10
1
p. 30
10) REFSTN-T
Refastening prohibited timer
0.0 to 9.9s
1.0
p. 30
11) COUNT-FNC
Count function
OFF / ON
CH1: ON
CH2: OFF
CH3: OFF
CH4: OFF
p. 31
12) WORK-SNSR
Workpiece signal
OFF / ON
OFF
p. 31
13) COUNT
Count number
1 to 99
1
p. 31
14) WORK-S-T
Workpiece setup time
0.0 to 9.9s
0.0
p. 31
15) CRT-T-L
Screw fastening time lower limit
value
0.00 to 9.99s
0.00
p. 32
16) CRT-T-U
Screw fastening time upper limit
value
0.01 to 9.99S / DIS
DIS
p. 32
17) OK-OUT-T
Screw fastening confirmation
time
0.0 to 9.9s
0.0
p. 33
18) OK-TIMING
OK output timing
C-F / W-O
C-F
p. 33
19) OK-BZ
Operations OK buzzer sound
OFF / 1 to 11
CH1: 1
CH2: 2
CH3: 3
CH4: 4
p. 33
20) NG-BZ
Operations NG buzzer sound
OFF / 1 to 10
1
p. 33
21) COUNT-RTN
Count return function
OFF / ON1 / ON2
ON1
p. 33
22) BZ-VOLUME
Buzzer sound volume
OFF to MAX
MAX
p. 34
23) CHECK-BZ
Check buzzer sound
OFF / ON
ON
p. 34
24) BACK LIGHT
Back light
OFF / ON
ON
p. 34
25) SETUP-RESET
Initialization of settings
ALL / CH1 / CH2 / CH3 / CH4
-
p. 24
z
z
No.1, No.22 to 24: All channels shared setting
z
z
No.12 to 21: Setting valid only when No.11 is “ON”
Even if the electric screwdriver is used to perform screw tightening during the setting mode, the count-up “C-UP” and
screw fastening NG “F-NG” output signals do not go ON.
TV07783-1_DLV10C_en.indb 23
2017/06/27 17:41:37