36
EN
Terminal
No.
Function
Details
I/O
3
Channel A
In the 2-bit input signal, specify the operations channel (CH1 to
CH4)
z
z
Valid only when “operations channel switching method” (No.1
CH-CHG) is set to “INPUT” (p. 25)
Input
4
Channel B
5
Forward rotation startup
Startup with external input signal (p. 45)
6
Reverse rotation startup
7
WORK
Input the workpiece signal (workpiece detection sensor output)
z
z
With “count function” (No.11 COUNT-FNC) and “workpiece
signal” (No.12 WORK-SNSR) set to ON, the workpiece signal
input is valid (p. 42)
8
WORK RESET
Reset operations (same as controller [WORK RESET] button
(p. 6))
9
Keylock
Lock the controller button operation
z
z
Disable the controller button operation, and prevent setting
changes by the operator (p. 46)
10
Input signal negative
common wire
Connect 0 V DC
z
z
Service power source (terminal No.2) or external 0 V DC power
source can be connected (see circuit drawing on p. 40)
11
Forward rotation signal
Set output signal during forward rotation to ON
Output
12
Reverse rotation signal
Set output signal during reverse rotation to ON
13
Count-up (C-UP)
Performance of normal screw tightening (torque-up) sets output
signal to 0.3 seconds ON
14
Screw fastening NG (F-NG)
If screw fastening NG, sets output signal to 0.3 seconds ON
15
Operations channel 1 (CH1)
Set the channel output signal to ON during operations or settings
16
Operations channel 2 (CH2)
17
Operations channel 3 (CH3)
18
Operations channel 4 (CH4)
19
Operations OK
If the set count screw tightening is judged to be completed and
operations OK, the output signal is set to ON
z
z
For OK output timing, see p. 33
20
Operations NG
When the WORK input signal is OFF during an operation, and the
operation is judged to be NG, the output signal is ON
21
Space
Connection impossible
22
Output signal positive
common wire
C24 V DC
z
z
Service power source (terminal No.1) or ex24 V DC can
be connected (see circuit drawing on p. 40)
Using External Signals
TV07783-1_DLV10C_en.indb 36