14
EN
Symptoms
Location to investigate
Solution
The electric screwdriver
gets hot
Is the ON time of the electric
screwdriver too long?
Alternatively, is the OFF time too
short?
Review the operation time.
The rated operating time is 0.5 sec. ON and 3.5 sec.
OFF.
Aim at 15 screws per minute. (p. 4)
Even though the output torque is set
to the specification lower limit value,
does the screwdriver get hot to a level
where you cannot touch it?
When the output torque becomes higher, the electric
screwdriver becomes hot.
If it gets hot to a level where you cannot touch even
with the specification lower limit value, a failure is
suspected.
Maintenance and inspection
WARNING
z
Before performing maintenance and inspection, always turn off the power.
z
Do not disassemble or alter the tool.
z
Use genuine parts.
CAUTION
z
For repair or part replacement, ask your dealer.
Repair requires special knowledge and skills. If repair is performed at a place other than a specialty store, the
tool may not demonstrate its full performance or it could lead to an accident or injury.
z
Request repair with the failed status kept intact.
When requesting a repair, do not throw away damaged parts. It could be important information for investigating
the failure cause so do not change the status.
For the purpose of making proper use, request the following check and maintenance by an authorized service facility.
DLV30A series
DLV45A series, DLV70A series
Routine inspections and Parts to be
replaced
Number of Tightening (million)
0.5
1.0
1.5
2.0
0.25
0.5
0.75
1.0
Routine inspection
(1) Operation check
{
{
{
{
{
*1
{
*1
{
*1
{
*1
(2) Grease-up
{
{
*2
{
*1
Parts to be replaced
(1) Motor assembly
{
{
*2
{
*1
(2) Gear
{
{
*2
{
*1
(3) Rollers and Balls
{
{
*2
{
*1
(4) Bearing
{
{
*2
{
*1
*1: DLV45A series, DLV70A series
*2: DLV70A series