Introduction
Receiving flow rate pulse signal from flow meter, batch counter
and so on, it prints totalized flow quantity per batch and total flow
rate per setting time.
■
Features
●
Enabling 2 input flow rate pulse
●
Indication 8 digits count and daily total, and 10 digits
monthly total and total.
●
Available for choose from 7 kind of indication unit.
●
Depend on the kind of pulse signal, max input frequency
can be set in 2 stages.
●
By memorizing a flow meter factor, it can be inputted
unscaled pulse. (option)
●
The channel name can be preset. (option)
●
Enabling confirmation of time by inner clock.
●
Available for reprint of last print in case of miss-print or
multiplicity print.
●
Panel mounting or set on the desk.
●
AC free power supply unit.
■
Specifications
Pulse input
Number of input
2 channel (Photo-coupler insulation)
No-contact input
Frequency
200Hz or under (ON/OFF ratio 1:1)
Type of signal
Voltage or open-collector pulse signal
Signal level
H:9
~
24V L:3V or under
Voltage & current Approx. 12V Approx. 6mA (with internal 12V
power source)
Approx. 24V Approx. 12mA (with external
24V power source)
Contact input
Frequency
20Hz or under (ON/OFF ratio 1:1)
Voltage & current Approx. 12V Approx. 6mA (in case of using
12V internal power source)
Approx. 24V Approx. 12mA (in case of using
24V external power source)
Counter
(No flow rate indication)
Count, daily total 8 digits counter (zero suppression print)
Monthly, total
10 digits counter (zero suppression print)
Scaling
(option)
Totalize with unscaled pulse. Need flow meter factor.
Multiplying factor 0.1000
~
1.000
Dividing factor
1/1, 1/10, 1/100, 1/1000, 1/10000
Decimal point
Chose from without /0.0 /0.00 /0.000 (setting with switch)
Naming
(option)
Requested names are set to each channels before delivery.
Standard name Channel1: 1CH Channel2: 2CH
Letter
Alphanumeric character up to 3 digits max.
Unit
Chose from cubic measure unit, mass unit or without
Unit: mL, L, m
3
, GAL, g, kg, t, without
Clock
Indication:
Indication as print when power on or total flow
rate print
Clock
Up to 31
st
December, 99, 23 hours 59
minutes 59 seconds
Leap
year
Set with the last 2 digits of Gregorian
calendar year and automatically renewed.
Time reference
Internal crystal oscillator
Daily difference: Within 4sec (0
~
40 )
Reference value: Approx. 0.5sec (25
±
3 )
Synchronization with supply frequency
Synchronize with commercial power supply
frequency (50Hz / 60Hz Set with switch)
Synchronization with input signal
Synchronize with external transmitter
Signal level H:9
~
24V L:3V or under
Indication
Flash on and off every one second (Feed switch S6) LED
indication (Red)
Operation
Setting procedure by manual operation switches (S3
~
S6)
S3: Left side (measuring): Normal measuring point
S4: Correct of clock with in
±
30 sec
S5: Manual print
S6: Feed the paper (1 line)
S3: Right side (time setting): Setting for time, flow unit, and
delay time.
S4: Adding volume, change measuring unit.
S5: Reduce volume, change measuring unit
S6: Print the setting, save the setting
Manual print
Enabling to check the total value with pushing S5 baton inside of
the sub-panel
Print the count, daily total, monthly total, and total of both
channels.
Auto print
Print the count, daily total, monthly total, and total of both
channels at each set time interval with reference to 0:00 on the
clock.
Interval time
1min, 5min, 30min, 1hr, 4hr, 12hr, 24hr, and
no-function. (Setting with switch)
Resetting Count: Reset at each print
Daily total: Reset on 24:00 at end of day.
Monthly total: Reset on 24:00 at end of month.
Total: Not reset
Printer PR2080D
Specifications
SSF50251 16.08
PR