Ambient temperature
0
~
+40
℃
(Without condensation)
Mass
Approx.
3kg
Casing
Material:
Sheet metal, plated (front)
Coating:
Munsell N1.5 Half-shine (black)
Sub-panel Acrylic plastic (smoky)
Accessories
Printing paper: 2 rolls Ribbon cassette: 1 pc.
Mounting fixture: 1set
■
External & panel cut dimensions
No. Contents
No. Contents
1
Setting switchs SW1, SW2
8
Lightning push-switch S
6
2
Print Mechanical
9
Roll paper
3
Paper cutter
10 Sub-panel
4
Printed paper outlet
11 Turminal of power input
5
Select-switch S3
12 Terminal of inputo or output
6
Push-switch S4
13 Rubber pods
7
Push-switch S5
14 Mounting fixture
Setting Switch
SW2 SW1
SW1
Setting
Contents
ON
Synchronization of internal frequency: 50Hz
OFF
Synchronization of internal frequency: 60Hz
SW1-1
SW1-2
SW1-3
Contents
ON
ON
Cubic measure unit: GAL (without)
OFF
ON
Cubic measure unit: m
3
(t)
ON
OFF
Cubic measure unit: L (kg)
OFF
OFF
Cubic measure unit: mL (g)
Unit inside of the ( ) can be changed as mass unit.
SW1-4
SW1-5
Contents
ON
ON
Decimal points: 0.000
OFF
ON
Decimal points: 0.00
ON
OFF
Decimal points: 0.0
OFF
OFF
Decimal points: non
SW1-6
SW1-7
SW1-8
Contents
ON
ON
ON
Interval time of auto-print: non
OFF
ON
ON
Interval time of auto-print: 24Hr
ON
OFF
ON
Interval time of auto-print: 12Hr
OFF
OFF
ON
Interval time of auto-print: 4Hr
ON
ON
OFF
Interval time of auto-print: 1Hr
OFF
ON
OFF
Interval time of auto-print: 30min
ON
OFF
OFF
Interval time of auto-print: 5min
OFF
OFF
OFF
Interval time of auto-print: 1min
SW2
Setting
Contents
ON
Input frequency in 1CH: Max. 20Hz
OFF
Input frequency in 1CH: Max. 200Hz
ON
Count direction of 1CH: Setting Low (H
→
L)
OFF
Count direction of 1CH: Setting High (L
→
H)
ON
Input frequency in 2CH: Max. 20Hz
OFF
Input frequency in 2CH: Max. 200Hz
ON
Count direction of 2CH: Setting Low (H
→
L)
OFF
Count direction of 2CH: Setting High (L
→
H)
SW2-1
SW2-2
SW2-3
SW2-4
■
Action
●
Turn on the main power
Printing time and Flash on and off every one second with red
light when turn on the power.
If time is different, please adjust with time setting.
●
Time setting and change the setting.
Do time adjustment within
±
30sec with S4 button switch.
Resetting of seconds only, for a difference less than 30
seconds. In the case of a difference of 30 seconds and over,
reset seconds and carry up to minute.
Turn select switch S3 to the time setting (right side) and
adjust the time difference or change the setting.
(1) Minute adjustment: After adjust with S4 (+), S5 (-), save
with pressing S6 button.
(2) Hour, day, month, year adjustment: same procedure.
(3) Indication unit setting: Change with S4 (+) and confirm
with pushing S6.
(4) Delay time of 1
st
digit setting: Same procedure as minute
adjustment.
(5) Delay time of 2
nd
digit setting: Same procedure as minute
adjustment.
Turn select switch S3 to the measure (left side) and finish the
setting.
●
Counting action
After turn on power, count pulse signal which input to 1CH or
2CH.
When count inhibit signal is ON, stop counting.
●
Printing action
There are 5 kinds of printing function as below, and kind of
printing function is printed in right side of time.
(1) Manual print (MAN)
(2) Auto-print (AUT)
(3) Print from print signal (PRINT)
(4) Print from reset signal (RESET)
(5) Print when total reset (TRES)
In manual print can check the count value of that time. No
reset after print.
Reset after print except for manual print. In case of reset, “R”
is printed on right side of the paper. In case of No reset, “N” is
printed on right side of the paper.
In case of use only 1CH etc, the channel of which value is
zero is not printed. In this case, usable as a printer only for
1CH
●
Reprint action
While pressing switch S6, press switch S5, and available for
reprint of last print. Please use in case of miss-print or
multiplicity print.
PR