background image

 

INTRODUCTION

  

  
Multitasking  self-leveling  laser  construction  levels  are  used  to  determine  the  height  in 
construction measurements. Model NL540 has a visible light beam and it can be used at work 
inside  and  outside  the  building.  The  device  is  powered  by  rechargeable  batteries  which  use 
advanced micro-controlled charging technology. 
  
NL  series  levels  may  designate  a  vertical  or  horizontal  laser  plane,  additionally  the  device 
defines  the  axis  of  the  laser  plane  (laser  line  -  point  up  and  down).  NL540  models  can  be 
controlled from the device control panel or remotely, with remote control.  
  
Laser level is waterproof and can be used outdoors, even in the rain.  However, these devices 
can’t be submerged in water  
 

Laser plumb up 

 

 

 

 

Laser module 

 

 

 

 

 

Optical glass 

 

 

 

 

 
 
 
             MENU / LCD 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

    Batteries   

 

 

 

                                      Handle 

Laser plumb down 

 

PRECAUTIONS  

 

WARNING

the

 device has a built in laser source which generates laser beam. It Is not allowed 

to disassembly the device by "your own".   
 

There is a risk of fire, electric shock, or injury while self-repair.

  

Repairs can be made only by Nivel System service or its authorized representatives.  

The laser beam can be hazardous to the human eye if the device is improperly operated.

  

Never repair the laser by your own.  

Protect your eyes from damage.

  

Never look into the laser beam  

Risk of fire and electric shock.

  

Summary of Contents for NL540

Page 1: ...1 ...

Page 2: ...ank you for purchasing a Nivel System NL540 laser level To best use the purchased instrument please read the instructions carefully and put in a convenient spot so that in the future you will be able to use it ...

Page 3: ...anel or remotely with remote control Laser level is waterproof and can be used outdoors even in the rain However these devices can t be submerged in water Laser plumb up Laser module Optical glass MENU LCD Batteries Handle Laser plumb down PRECAUTIONS WARNING the device has a built in laser source which generates laser beam It Is not allowed to disassembly the device by your own There is a risk of...

Page 4: ...ged transport box or transport box latches can lead to falling out of the box and damage the laser The collapse of laser level to the ground can lead to damage Shaky unstable site of laser level can lead to collapse and damage the laser Always make sure that all screws and latches in a tripod works properly Exclusions of liability 1 It is expected from the user to comply all recommendations regard...

Page 5: ...ully charged charging normally takes 7 hours to give 50 hours of use Use lasers NL540 with care protect from moisture Never put a wet instrument to the transport box wait until dry CONTROL PANEL Description of buttons and functions On off power and switch to manual mode Turns on and off Longer press of a button approx 6 seconds when the equipment is turned on enables disables the manual mode The e...

Page 6: ...de available via remote controller The scan Mode is to be used when you want the beam focused on a smaller range Press the button panel of remote controller for a single point Press the same button to get angles of approximately 10o 45o 90o and 180o directional scan button narrowing of the laser line in the required range where the work is carried out available display of beam angles 0 10 45 90 18...

Page 7: ...n a staff and by remote control change the inclination of the laser plane in order to fit in the position of the laser sensor this shift of laser sensor will specify the inclination eg If you want to get a inclination of 1 at a distance of 10 m laser staff the difference between the height of the zero point on the staff should and designated inclination should be 10 cm Working with the vertical pl...

Page 8: ... 2 Turn on the instrument and wait until it level automatically 3 Place a sheet of paper on the wall Mark the position of the laser beam on the sheet Turn off the instrument 4 Loosen the tripod fixing screw and rotate the instrument 180 WARNING Be careful not to move the instrument while the head is spinning 5 Turn on the instrument once again and wait until it level automatically 6 Once again mar...

Page 9: ...between the markers 7 Do not change the position of the laser and spin it 180 8 Mark the position of the laser beam on the paper sheet Measure the distance between the markers 9 If the distance between the markers is less than 3mm calibration is not necesery LASER SENSOR RD200 LCD Display Precise mode Coarse mode Too high the laser signal is below please Lower the sensor you will hear a high frequ...

Page 10: ... zero LED grade indicator lbubble keypad magnet unit mm cm cal On Off Beeper volume deadband resolution LED On Off Display numeric text display grade indication arrows on grade indicator low battery grade indication arrows accuracy 1 2 5 10 mm beeper volume Battery ...

Page 11: ...al sensor digital NL BR bracket of RD200 Tripod adapter 0 90 NL BR600 bracket of RD700 Charger YR półka laserowa TR R laser target GL laser glasses Laser case Remote controller RC 5 DS SJJ1 tripod SJJ32 tripod 3 2m LS 24 laser staff 2 4m LS 35 laser staff 3 5m ...

Page 12: ...be charged for unjustified complaints in accordance with the effective price lists Warranty repairs shall be carried out only and exclusively based on purchase document Under the warranty the Warrantor shall not be liable for the consequences of defects that is damage caused to people third parties property lost profits etc 2 The warranty shall be terminated if the following is found the standards...

Page 13: ... battery auto turning off The sensor is automatically turn off in 30min if it will not detect a laser beam if you want to turn the sensor on once again please press the power button Working temperature from 20 C to 50 C Dimensions 135 x 65 x 24 5 mm Weight 0 15 kg Laser sensor RD700 Digital specification Capture height 90 mm Numeric readout height 80 mm Reception angle 45 Detectable spectrum 450 n...

Page 14: ...kupienie niwelatora laserowego firmy Nivel System model NL540 Aby móc jak najlepiej wykorzystać zakupiony instrument prosimy uważnie przeczytać instrukcję i położyć w dogodnym miejscu żeby w przyszłości móc z niej skorzystać ...

Page 15: ... mikro kontrolowanego ładowania Niwelatory serii NL mogą wyznaczać pionową lub poziomą płaszczyznę laserową dodatkowo urządzenia wyznaczają oś płaszczyzny laserowej laser liniowy punkt do góry i punkt do dołu Model 540 może być sterowany zarówno z panelu kontrolnego urządzenia jak i zdalnie z pilota Niwelator jest wodoszczelny i może pracować na zewnątrz także podczas deszczu Jakkolwiek urządzeń t...

Page 16: ...nikające z tego powodu straty Niewłaściwe użycie lasera oraz stosowanie go niezgodnie z opisanymi w tej instrukcji procedurami może spowodować obrażenia lub narażenie się na nadmierną dawkę promieniowania Nie można pozwolić aby ktokolwiek pracował w promieniu lasera Przed rozpoczęciem pracy należy upewnić się że wiązka lasera znajduje się ponad głowami pracowników Oświetlenie wiązką laserową może ...

Page 17: ...540 zastosowano akumulatorki litowo jonowe które mogą być ładowane Ładowanie akumulatorków odbywa się za pośrednictwem ładowarki na wyposażeniu standardowym za pomocą złącza znajdującego się na panelu frontowym niwelatora Ładowanie sygnalizowane jest zapaleniem się diody na zasilaczu W przypadku gdy ładowarka nie jest podłączona dioda miga czerwonym kolorem gdy jest w trakcie ładowania dioda pali ...

Page 18: ...hylone Jeśli praca lasera zostanie zakłócona przez wstrząs uderzenie usłyszymy sygnał dźwiękowy alarmu wskazujący że laser mógł się poruszyć głowica przestanie się kręcić Pozostałe funkcje Another Functions Tryb skanowania dostępny za pośrednictwem pilota zdalnego sterowania Tryb skanowania używamy gdy chcemy zawęzić wiązkę laserową nakreślić linię lasera w zawężonym zakresie Naciśnij przycisk pan...

Page 19: ...a położenia czujnika na łacie wskaże różnicę wysokości mierzonego punktu w porównaniu z reperem Praca z płaszczyzną pionową NL540 może wyznaczać wiązkę poziomą lub pionową W przypadku pracy z wiązką pionową laser należy ustawić go w pozycji pionowej Po włączeniu urządzenie samo spoziomuje się głowica zacznie obracać się wyznaczając płaszczyznę pionową Pionownik laserowy górny wyznacza linię prosto...

Page 20: ...ywał ścianę 2 Włącz instrument i poczekaj aż zakończy się automatyczne poziomowanie 3 Umieść na ścianie kartkę papieru Zaznacz na kartce położenie promienia lasera Wyłącz instrument 4 Poluzuj śrubę sercową statywu i obrócić instrument o 180 Uwaga Należy uważać żeby nie potrącić instrumentu w trakcie obracanie się głowicy 5 Włącz instrument ponownie i poczekaj aż zakończy się automatyczne poziomowa...

Page 21: ...nikami 7 Nie zmieniając pozycji lasera obróć go o 180 8 Zaznacz na kartce miejsce położenia promienia lasera Pomierz odległość między znacznikami 9 Jeśli różnica odległości jest mniejsza niż 3 mm kalibracja nie jest konieczna CZUJNIK LASEROWY RD200 Wyświetlacz LCD Tryb precyzyjny Tryb zgrubny Za wysoko sygnał laserowy znajduje się poniżej obniż czujnik słyszalny będzie dźwięk wysokiej częstotliwoś...

Page 22: ...znie i wyłączanie zasilania sygnalizatora dżwiękowego zmiana trybu pracy dokładność włączenie wyłączenie sygnalizatorów LED Wyświetlacz wskazania różnicy wysokości wskazania przewyższenia powyżej zera wskazania przewyższenia poziom poziom naładowania baterii zero wskazania przewyższenia poniżej zero tryb pracy dokładność sygnalizator dźwiękowy w zakresie 1 2 5 10 mm Komora baterii ...

Page 23: ...ket of RD200 Tripod adapter 0 90 NL BR600 bracket of RD700 Ładowarka YR półka laserowa TR R tarczka laserowa GL R okulary laserowe Waliza transportowa Pilot zdalnego sterowania RC 5 DS SJJ1 statyw aluminiowy SJJ32 statyw aluminiowy LS 24 łata laserowa 2 4m korbowy 32m LS 35 łata laserowa 3 5m ...

Page 24: ... W ramach gwarancji Gwarant nie ponosi odpowiedzialności z tytułu skutków usterek tj szkód wyrządzonych ludziom zniszczenia cudzej własności strat w zyskach itp 2 Gwarancja traci ważność w przypadku stwierdzenia przekroczenia norm użytkowania sprzętu uszkodzeń powstałych w wyniku użytkowania sprzętu niezgodnie z instrukcją obsługi uszkodzeń mechanicznych dokonywania przez użytkownika napraw we wła...

Page 25: ...omatyczne wyłączanie Czujnik wyłączy się automatycznie jeśli przez 30min nie wykryje promienia laserowego Żeby włączyć czujnik należy ponownie nacisnąć przycisk zasilania Temperatura pracy 20 C do 50 C Wymiary 135 x 65 x 24 5 mm Waga 0 15 kg Specyfikacja czujnika laserowego RD700 Digital Zakres detekcji 90 mm Numeryczne wskazanie zakres 80 mm Kąt odbioru wiązki 45 Odbiór wiązki laserowej 450 nm 80...

Page 26: ...ing laser level Trade mark Nivel System Model NL540 Serial number The date of the check Instrument checked and calibrated Calibration technician EC declaration of conformity We declare that products Nivel System NL540 conform to EN 61010 1 2010 EN 61326 1 2013 ...

Page 27: ...27 WARNING The device contains a rechargeable Li ion batteries which must be recycled and should be disposed in accordance with the requirements ...

Page 28: ...28 ...