background image

 

indicate the height differences of the measured point compared to the benchmark.  
 

Slope determination 
 

Set the laser level on a tripod. Set the laser level in the axis you want to tilt and turn on the laser 
level. The laser plummet (bottom) indicates the first point of the axis, on the other end point set 
the laser staff with laser sensor  -  reset  position (sensor and staff). Depending on the desired 
value of inclination slide the sensor on a staff and by remote controll change the inclination of 
the  laser  plane  in  order  to fit  in  the position  of  the  laser  sensor  (this  shift  of  laser  sensor  will 
specify the inclination, eg.  If  you want  to get a inclination of  1%, at  a distance of  10 m (laser 
staff)  the  difference  between  the  height  of  the  zero  point  on  the  staff  should  and  designated 
inclination should be 10 cm).    
 

Working with the vertical plane

  

 
NL810  can  set  horizontal  or  vertical  beam.  If  you  work  with  a  vertical 
laser beam you must set the laser level as in the picture beside.  

 
Remote control 
 

Features  of  NL810  laser  level  can  be  controlled  remotely  using  the 
remote  control.  On  the  remote  control  panel  there  are  buttons  that 
correspond  to  those  included  on  the  front  panel  of  laser  level.  The 
operating range of remote control is approximately 20 meters (depends on the conditions on the 
site)  
The procedure for changing the transmission channel. 
Changing the channel must be carried out separately on the remote control and laser level. 
 
Changing the channel on the remote control: 
• Turn the remote by on/off switch by holding it so long until you see the blinking icon 
similar to the phone and will be displayed next to the channel number. 
• Change the channel number by pr or -. 
• Confirm by holding down the power button on remote control. 
 
Changing the channel in laser level: 
• Turn the laser level. 
• Hold the X / Y for about 5 seconds. You will see the blinking icons: 
antenna and channel number. 
• Change the channel number using the + or - on the same as the one set 
the remote control. 
• Remember, holding the X / Y until turns off the channel number. 
• antenna icon continue to blink. 
• Then turn off the laser level and turn it on again. 
• non-blinking antenna icon indicates a proper connection with the remote 
 
NOTE: 
In exceptional cases, you may experience instability working of laser level in cooperation with 
the remote control. This is caused by data transmission system between the remote control and 
leveling tool. The communication system is based on a radio transmitter operating on UHF. In 
this range there are multiple transmission systems and their frequencies can interfere with each 
other.  In  the  case  of  unstable  behavior  leveling  change  the  channel  on  the  remote  control 
communicates with the leveling tool.  

Summary of Contents for NL810

Page 1: ...r NL810 Thank you for purchasing a Nivel System NL810 laser level To best use the purchased instrument Please read the instructions carefully and put in a convenient spot so that in the future you will be able to use it ...

Page 2: ...2 NOTE The device comprises a nickel hydrogen batteries the batteries must be recycled and should be disposed of in accordance with the requirements WEEE Reg DE23874031 ...

Page 3: ...it it s possible to stop the beam at a given distance NL810 models can be controlled from the device control panel or remotely with remote control Laser level is waterproof and can be used outdoors even in the rain However these devices can t be submerged in water Rotating head Windows which security laser heads Control panel Collimator AC input Handle Battery holder PRECAUTIONS WARNING the device...

Page 4: ...he acid leaking from batteries and accumulators However if it occurs quickly wash the body with clean water and consult a doctor Broken or damaged transport box or transport box latches can lead to falling out of the box and damage the laser The collapse of laser level to the ground can lead to damage Shaky unstable site of laser level can lead to collapse and damage the laser Always make sure tha...

Page 5: ... NL810 with care protect from moisture Never put a wet instrument to the transport box wait until dry CONTROL PANEL 4 8 3 7 2 6 1 5 Description of buttons and functions 1 On off power and switch to manual mode Turns on and off Longer press of a button approx 6 seconds when the equipment is turned on enables disables the manual mode The equipment in manual mode can be tilted beyond self leveling or...

Page 6: ...ads turn to the right when the head is not spinning or level is switched into scan mode 8 PLUS counter clockwise rotation Use the key to add the value of inclination plus turn heads left WORKING WITH LASER LEVEL Turning on the power On the front panel press button 1 The instrument will level by itself and the power LED lights up Press the button again to turn off the power Once leveled up the lase...

Page 7: ... automatically leveled 1 Establish a target line parallel to desired direction of grade 2 Set up the laser over this line drop a plumb bob from the tripod mounting screw 3 Rough align the instrument to the direction of grade 4 Place a rod or other target down range on the target line 5 While sighting through the collimator adjust the instrument until the sight is aligned with the target PRINCIPLE ...

Page 8: ... meters depends on the conditions on the site The procedure for changing the transmission channel Changing the channel must be carried out separately on the remote control and laser level Changing the channel on the remote control Turn the remote by on off switch by holding it so long until you see the blinking icon similar to the phone and will be displayed next to the channel number Change the c...

Page 9: ...s perpendicular to the wall and X direction a pointed to a wall Turn on the instrument and wait until it level automatically Place a sheet of paper on the wall Mark the position of the laser beam Ma on the sheet Turn off the instrument Loosen the tripod fixing screw and rotate the instrument 180 WARNING Be careful not to move the instrument while the head is spinning Turn on the instrument once ag...

Page 10: ...ccur Warning If this error is more than 3m you should contact the service center Checking the vertical plane This procedure should be done after calibration of the horizontal plane Checking Set the laser centered between the walls distanced from each other of 30 m Turn on the laser level Place the paper sheets on the walls and mark the position of the laser beam Turn off the instrument Set the ins...

Page 11: ...the power button Working temperature from 20 C to 50 C Dimensions 135 x 65 x 24 5 mm Weight 0 15 kg 2 LCD Display Precise mode Coarse mode Too high the laser signal is below please Lower the sensor you will hear a high frequency sound You are in the right position you will hear a continuous sound Too low the laser signal is above you will hear a high frequency sound buzzer on discharged batteries ...

Page 12: ... 160 x 240 mm Weight 3 2 kg Remote control technical specification Working range about 30 m outside about 20m Warning AC Adapter could not be used outside Do not use it for charging alkaline batteries Device look such as tech spec could be changed without any information for customer Free extended warranty 24 months To use the free warranty extension to 24 months the instrument must be registered ...

Reviews: