background image

1-4 Operation 

  Do  not  disconnect  the mains  cable  on the  UPS  system  or  the  building  wiring  outlet 

(shockproof  socket  outlet)  during  operations  since  this  would  cancel  the  protective 
earthing of the UPS system and of all connected loads.   

  The UPS system features its own, internal current source (batteries). The UPS output 

sockets or output terminals block may be electrically live even if the UPS system is 
not connected to the building wiring outlet.   

  In  order  to  fully  disconnect  the  UPS  system,  first  press  the  OFF/Enter  button  to 

disconnect the mains.   

  Prevent no fluids or other foreign objects from inside of the UPS system.   

1-5 Maintenance, service and faults 

  The UPS system operates with hazardous voltages. Repairs may be carried out only 

by qualified maintenance personnel.   

 

Caution

 - risk of electric shock. Even after the unit is disconnected from the mains 

(building wiring outlet), components inside the UPS system are still connected to the 
battery and electrically live and dangerous.   

  Before carrying out any kind of service and/or maintenance, disconnect the batteries 

and verify that no current is present and no hazardous voltage exists in the terminals 
of high capability capacitor such as BUS-capacitors.   

  Only  persons  are  adequately  familiar  with  batteries  and  with  the  required 

precautionary  measures  may  replace  batteries  and  supervise  operations. 
Unauthorized persons must be kept well away from the batteries.   

 

Caution

 - risk of electric shock. The battery circuit is not isolated from the input voltage. 

Hazardous voltages may occur between the battery terminals and the ground. Before 
touching, please verify that no voltage is present!   

  Batteries may cause electric shock and have a high short-circuit current. Please take 

the precautionary measures specified below and any other measures necessary when 
working with batteries:   

remove wristwatches, rings and other metal objects   

use only tools with insulated grips and handles.   

  When changing batteries, install the same number and same type of batteries.   

  Do  not  attempt  to  dispose  of  batteries  by  burning  them.  This  could  cause  battery 

explosion.   

  Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and 

eyes. It may be toxic.   

  Please replace the fuse only with the same type and amperage in order to avoid fire 

hazards.   

  Do not dismantle the UPS system.   

 

 

 

 

Summary of Contents for NUPS23 Series

Page 1: ...s Niveo Professional True Sine Wave Double Conversion Online Rack Tower UPS NUPS23 1000 1 0KVA 900W NUPS23 2000 2 0KVA 1800W NUPS23 3000 1 0KVA 2700W More information WWW NIVEOPROFESSIONAL COM INFO NI...

Page 2: ...this guide 4 2 Installation and setup 4 2 1 Unpack checking 4 2 2 Real panel view 4 2 3 LCD control panel 6 2 4 Setup the UPS 6 3 Operations 8 3 1 Button operation 8 3 2 LCD display 9 3 3 UPS setting...

Page 3: ...nt The UPS system must be absolutely dry before being installed Please allow at least two hours for the UPS system to acclimate the environment Do not install the UPS system near water or in moist env...

Page 4: ...ies and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS capacitors Only persons are adequately familiar with batteries and w...

Page 5: ...ease keep the original package in a safe place for future use 2 1Unpack checking Don t lean the UPS when moving it out from the packaging Check the appearance to see if the UPS is damaged or not durin...

Page 6: ...5 2KVA S 2KVA H 3KVA H 3KVA S...

Page 7: ...erminal 10 Output Terminal 2 3LCD control panel LCD control panel introduction 1 LED from top to bottom alarm bypass battery inverter 2 LCD display 3 Selectbutton enter to next item 4 Off button 5 On...

Page 8: ...ftware installed you can schedule UPS shutdown start up and monitor UPS status through PC The UPS is equipped with intelligent slot perfect for either SNMP or Relay card When installing either SNMP or...

Page 9: ...is normal press and hold this button for 2 seconds Then UPS will enter to bypass mode This action will be ineffective when the input voltage is out of acceptable range Up key Press this button to disp...

Page 10: ...9 3 2LCD display There are 8 interfaces available in the LCD display Item Interface Description Content Displayed 01 Input voltage 02 Battery voltage 03 Output voltage...

Page 11: ...10 04 Load 05 Temperature Environment Temperature Heatsink Temperature 06 Firmware Version UPS model...

Page 12: ...as below while the charger is on 3 3UPS setting The setting fuction is controled by 3 buttons Enter Select Off up On down Enter Off up goes into the setting page Enter value adjustment Off On for cho...

Page 13: ...127 or 200 208 220 230 240 Press UP button to select the previous setting Press DOWN button to select the next setting 03 Frequency setting Press select button to change the setting 50 or 60Hz Press U...

Page 14: ...lect the next setting 06 Bypass voltage lower limit setting Press select button to change the setting The bypass voltage lower limit range is 170 220Vac Press UP button to select the previous setting...

Page 15: ...he acceptable range or power failure and alarm is sounding every 4 second UPS will backup power from battery Battery led light Standby mode UPS is powered off and no output supply power but still can...

Page 16: ...ure Twice per second Fault LED lit 26 Battery over voltage Once per second Fault LED blinking 29 Output Short circuit Once per second Fault LED blinking 30 Input current limit Once per second Fault LE...

Page 17: ...ler Alarm code is shown as 34 and battery led blinking Battery voltage is too low or the charger is fault Contact your dealer Alarm code is shown as 32 and INV or BYPASS led blinking UPS is overload R...

Page 18: ...ler Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperatur...

Page 19: ...cy range 40 70Hz Power factor 0 99 100 load Nominal Input Voltage Bypass voltage range Bypass high voltage point 230 264 setting the high voltage point in LCD from 230Vac to 264Vac Default 264Vac Bypa...

Page 20: ...S transfer to bypass after 1minute when the utility is normal 110 130 UPS transfer to bypass after 5 seconds when the utility is normal 130 UPS transfer to bypass immediately when the utility is norma...

Reviews: