Outputs
1 x switchable sensor supply
l
Standard: 15...19,5VDC, max. 66mA
l
Order option: 24...31VDC, max. 41mA
1 x isolated switch contact
l
I
max
: 130mA
l
U
max
: 32V
l
R
on
: 35Ω
l
f
max
: 500Hz
Additional information is provided in "Technical details regarding the outputs " on page
29.
Data memory
Internal flash memory for up to 25.580 measurement cycles
Data type
f32 (32 Bit floating point)
Data transmission
By means of GSM/GPRS quad-band modem to the relevant Device to Web server
SIM
The NivuLog Easy is equipped with an integrated SIM chip.
Monthly data volume <4MB for two minute measurement cycle and 120 minute transmission cycle
10 of 73
NivuLog Easy - Rev. 05 as of 02.07.2012