Chapter 7 Installation
U
max
V
batt
Low
<100mV
High
>200mV
Load
220k1
7.4.4 Technical details regarding the outputs
7.4.4.1 Output 1: Switchable sensor supply (V
out
)
Note:
The switchable sensor supply output is short-circuit-proof.
P
max
1W
I
max
66mA
@15V
41mA
@24V
7.4.4.2 Output 2: Isolated switch contract (NO, CC)
Important note:
The user must ensure that the current does not exceed 130mA via the isolated
switch contact.
Replacement circuit diagram for the isolated switch contact
I
max
130mA
U
max
32V
R
on
35Ω
f
max
500Hz
7.4.4.3 Direct accu or battery voltage output (V
batt
)
The accu or battery voltage is supplied directly to the voltage output V
batt
protected by a PTC (I
max
200mA).
The voltage available at this output is therefore directly dependent on the charging condition of the accu or
battery pack.
NivuLog Easy - Rev. 05 as of 02.07.2012
29 of 73