Revision A
Using the Buttons
The buttons are labelled with SET,
▼
(down), and
▲
(up)
.
When your clock is showing
the time, you can press
▲
to show the date and then the temperature. Also on the time
screen, pressing
▼
will cycle through the LED lighting colours.
If in a settings mode and no button has been pressed for 30 seconds, the display will
revert back to the normal time screen without saving.
Setting the Time
Press the SET button briefly and the display will be changed to only show the hour digits.
Press the
▲
and
▼
buttons to set the hour and SET to advance to the minutes to do the
same. After adjusting the minutes, pressing SET again will save the new time and return
to the normal time screen.
Changing your Settings
Hold the SET button for 3 seconds and the display will enter the settings menu. The
leftmost digit shows the setting number, and the rightmost digits show the current value
–
use the
▲
and
▼
buttons to adjust. Press the SET button briefly to advance to the
next setting, and at the end of the settings list it will save all changes and return back to
the normal time screen. The ordering and description of these options are shown below.
Setting
Number
Description
Usage
1
Set day-time tube
brightness
Use
▲
and
▼
to set tube brightness from 0
(min) to 7 (max).
2
Set night-time tube
brightness
3
Set night-time light
threshold
Press
▲
to use the current ambient light
level as the night-time detection threshold.
Press
▼
to use existing threshold.
“1” = New night
-time threshold will be set
“0” = No change to threshold level
4
Set custom LED colour
Cycle through LED colours by holding
▲
or
▼
and release on the desired colour. To
show the custom colour on the normal time
screen, exit the menu and use
▼
to cycle
through presets until new colour is selected.
Note: no value is shown on right side of
display.
5
Set LED brightness
Use
▲
and
▼
to set LED brightness, applied
to all screens.
Note: no value is shown on right side of
display.
6
Select 12hr or 24hr time
format
Use
▲
and
▼
to choose time format.
“1” = 12
-hour
“0” = 24
-hour
7
Select °C or °F
temperature
Use
▲
and
▼
to choose temperature units.
“1” = °F (Degrees Fahrenheit)
“0” = °C (Degrees Celsius)
Troubleshooting
Please refer to the full user’s guide for troubleshooting:
https://nixlabs.com.au/support/
For further support, contact
Specifications
Dimensions & Mass:
117mm x 55mm x 62mm (LxWxH), 115g
Operating Environment:
0°C to +40°C,
≤
95%rh non-condensing
Time Accuracy:
Calibrated to < 0.0003% (3ppm), < 8s per month @ 25°C
Temperature Accuracy:
0.1°C Resolution, ±3°C Accuracy (typ <1.5°C)
Time + Settings Backup:
4-day supercapacitor backup maintains time and date.
User settings are saved permanently.
Supplied Power Adaptor:
Input voltage: 90-250VAC, with Multi-Region plugs.
Output: 5.1V at 1A
Supply Voltage:
4.7V
–
5.5V via Standard Micro-USB Socket
Max Supply Current
145 mA (0.7W)
WebApp Compatibility:
WebUSB on Google Chrome version 61 or later, running
on Windows, Mac, Linux, ChromeOs and Android.