 Do not install the UPS system where it would be exposed to direct 

sunlight or near heat sources.

• 

Do not block ventilation holes in the UPS housing.

Installation

• 

 Do not connect appliances or devices which would overload the 

UPS system (e.g. laser printers) to the UPS output sockets.

• 

 Place cables in such a way that no one can step on or trip over 

them.

• 

 Do not connect domestic appliances such as hair dryers to UPS 

output sockets.

• 

 The UPS can be operated by any individuals with no previous 

experience.

• 

 Connect the UPS system only to an earthed shockproof outlet 

which must be easily accessible and close to the UPS system.

• 

 Please use only VDE-tested, CE-marked mains cable (e.g. the 

mains cable of your computer) to connect the UPS system to the 

building wiring outlet (shockproof outlet).

• 

 Please use only VDE-tested, CE-marked power cables to connect 

the loads to the UPS system.

• 

 When installing the equipment, it should ensure that the sum of 

the leakage current of the UPS and the connected devices does not 

exceed 3.5mA.

Operation

• 

 Do not disconnect the mains cable on the UPS system or 

the building wiring outlet (shockproof socket outlet) during 

operations since this would cancel the protective earthing of the 

UPS system and of all connected loads.

• 

 

The UPS system features its own, internal current source 

(batteries). The UPS output sockets or output terminals block may 

be electrically live even if the UPS system is not connected to the 

building wiring outlet.

• 

 In order to fully disconnect the UPS system, first press the OFF/

Enter button to disconnect the mains.

• 

 Prevent fluids or other foreign objects from entering the inside of 

the UPS system.

Maintenance, service and faults

• 

 The UPS system operates with hazardous voltages. Repairs may 

be carried out only by qualified maintenance personnel.

• 

 Caution - risk of electric shock. Even after the unit is disconnected 

from the mains (building wiring outlet), components inside the 

UPS system are still connected to the battery and electrically live 

and dangerous.

• 

 Before carrying out any kind of service and/or maintenance, 

disconnect the batteries and verify that no current is present and 

no hazardous voltage exists in the terminals of high capability 

capacitor such as BUS-capacitors.

• 

 Only persons are adequately familiar with batteries and with 

the required precautionary measures may replace batteries and 

supervise operations. Unauthorized persons must be kept well 

away from the batteries.

• 

 Caution - risk of electric shock. The battery circuit is not isolated 

from the input voltage. Hazardous voltages may occur between 

the battery terminals and the ground. Before touching, please 

verify that no voltage is present!

• 

 Batteries may cause electric shock and have a high short-circuit 

current. Please take the precautionary measures specified in this 

manual and any other measures necessary when working with 

batteries: remove wristwatches, rings and other metal objects, use 

only tools with insulated grips and handles.

• 

 When changing batteries, install the same number and same type 

of batteries.

• 

 Do not attempt to dispose of batteries by burning them. This could 

cause battery explosion.

• 

 Do not open or destroy batteries. Escaping electrolyte can cause 

injury to the skin and eyes. It may be toxic.

• 

 Please replace the fuse only with the same type and amperage in 

order to avoid fire hazards.

• 

Do not dismantle the UPS system.

Summary of Contents for Balder 1500

Page 1: ...Balder Series User Manual Manual de utilizare PWUP OL150BA AZ01B PWUP OL300BA AZ01B v 1 Before using this product carefully read all product documentation and retain it for future reference...

Page 2: ...alderSeries Balder 1500 Balder 3000 1500VA 3000VA Thank you for purchasing our products Please read this manual before using the product Focusing on quality at competitive prices nJoy designs consumer...

Page 3: ...r 3000 U S B E P O O U T R S 2 3 2 I N N E T W O R K F A X M O D E M I N T E L L I G E N T S L O T P R O G R A M M A B L E O U T L E T S P 1 O U T P U T I N P U T 1 0 A m a x English Rom n USB EPO OUT...

Page 4: ...luids or other foreign objects from entering the inside of the UPS system Maintenance service and faults The UPS system operates with hazardous voltages Repairs may be carried out only by qualified ma...

Page 5: ...ect battery wires please follow below steps Step 2 Connect to External Battery Pack When connecting external battery packs please be sure to connect polarity correctly Connect positive pole of battery...

Page 6: ...ical devices to the general outlets During power failure you may extend the backup time to critical devices by setting shorter backup time for non critical devices DoNOTplugLASER PRINTERSintoanyof the...

Page 7: ...o connect RS 232 USB port of UPS and RS 232 USB port of PC Install the UPS monitoring software from https www power software download com viewpower html to fully configure UPS shutdown Operations 5 Bu...

Page 8: ...nute S second Configuration and fault information 88 SET Indicates the configuration items and the con figuration items are listed in details in section 5 5 88 FAULT CODE Indicates the warning and fau...

Page 9: ...Indicators 5 3 LCD display wordings index 5 4 Mode Alarm Battery Mode Sounding every 5 seconds Low Battery Sounding every 2 seconds Overload Sounding every second Fault Continuously sounding Bypass Mo...

Page 10: ...e settings options or values for each program Interface Settings 01 Output voltage settings Parameter 2 Output voltage 200 presents output voltage is 200Vac 208 present output voltage is 208Vac 220 pr...

Page 11: ...le or disable Bypass function You may choose the following two options ENA Bypass enable DIS Bypass disable Default 07 Bypass voltage range setting Parameter2 Set theacceptable high voltagepoint andac...

Page 12: ...ng current based on battery capacity used Please use the following table as reference Battery capacity AH Total charging current A 7 20 2 20 40 4 40 60 6 60 80 8 80 100 10 100 150 12 NOTE If you conne...

Page 13: ...in parameter 2 Default 110Vac 00 Exit setting Exit the setting mode Operating Mode Description 5 6 Operating mode Description LCD display Online mode When the input voltage is within acceptable range...

Page 14: ...ashing Code Alarm Low Battery bL Sounding every 2 seconds Overload OL Sounding every second Over input current OI Sounding 2 beep every 10 seconds Battery is not connected NC Sounding every 2 seconds...

Page 15: ...gs cautions and notes before replacing the batteries CAUTION Step 1 Remove front panel Step 2 Disconnect battery wires Step3 Pull out the battery box by removing the two screws on the front panel Step...

Page 16: ...battery terminals by following below chart Battery kit assemly procedure 6 1 Balder 1500 Step 1 Remove adhesive tapes Step 2 Connect all battery terminals by following below chart Step 3 Put assemble...

Page 17: ...service unit Problem Possible Cause Solutions Fault code is shown as 28 on LCD display and alarm is continuously sounding Battery voltage is too low or the charger is fault Contact service unit The ic...

Page 18: ...12 13 and 41 on LCD display and alarm is continuously sounding A UPS internal fault has occurred There are two possible results 1 The load is still supplied but directly from AC power via bypass 2 Th...

Page 19: ...00 3000 Mul umim pentru c a i ales produsele noastre V rug m citi i cu aten ie manualul de utilizare nainte de a pune n func iune acest produs Concetr ndu ne pe calitate la pre uri competitive constru...

Page 20: ...e urgen 9 Conector pentru cabinetul de baterii Balder 1500 U S B E P O O U T R S 2 3 2 I N N E T W O R K F A X M O D E M I N T E L L I G E N T S L O T P R O G R A M M A B L E O U T L E T S P 1 O U T P...

Page 21: ...ntru a deconecta sursa de alimentare Nu l sa i s ajung n interiorul unit ii UPS niciun obiect str in sau lichide ntre inere Service i Defecte Sistemul UPS func ioneaz cu tensiuni periculoase Repara ii...

Page 22: ...ta aceste cabluri v rug m s urma i pa i de mai jos Pasul 2 Conectare cabinet de baterii extern Atunci c nd conecta i UPS ul la un cabinet de baterii extern asigura i v c polaritatea este corect polul...

Page 23: ...i de curent pute i extinde timpul de backup la dispozitivele critice set nduntimpmaiscurtdebackuppentrudispozitivele non critice NU conecta i imprimante laser la nici una din prizele UPS ului NU conec...

Page 24: ...utoane 5 1 Butonul ON Mute Pornirea UPS ului Ap sa i i ine i ap sat butonul ON Mute pentru cel pu in 2 secunde pentru a porni UPS ul Oprirea alarmei C nd UPS ul este n modul de baterie ine i ap sat ac...

Page 25: ...Indic baterie func ional Indic faptul c UPS ul se ncarc de la re ea BYPASS Indic faptul c circuitul bypass func ioneaz ECO Indic faptul c Modul ECO e activat Indic faptul c circuitul AC DC func ioneaz...

Page 26: ...at DIS d15 Dezactivat ESC ESC Renun HLS HLS Prag superior LLS LLS Prag inferior AO AO Deschidere activ AC AC nchidere activ EAT EAt Autonomie r mas estimativ RAT rAt Autonomie acumulat SD Sd nchidere...

Page 27: ...nstabil EE EE Eroare EEPROM BR bR nlocuie te bateriile Interfa Set ri 01 Set ri tensiune la ie ire Parametrul 2 Tensiune la ie ire 200 tensiunea de ie ire este 200Vac 208 tensiunea de ie ire este 208V...

Page 28: ...az sau deactiveaz func ia de bypass Pute i alege una din urm toarele op iuni ENA Activare bypass DIS Dezactivare bypass implicit 07 Set rile plajei tensiunii de bypass Parametrul2 Stabili i valoareama...

Page 29: ...u valoarea maxim a curentului de nc rcare Dac folosi i cabinete de baterii externe v rug m s seta i valoarea maxim a curentului de nc rcare conform cu tabelul de mai jos Capacitate baterie AH Curent d...

Page 30: ...itele acceptate dar UPS ul este supra nc rcat va intra in Modul Bypass automat Alarma va suna o dat la fiecare 10 secunde 17 Conectarea unui transformator de izolare extern Parametru 2 Permite sau nu...

Page 31: ...re 2 secunde Frecven de bypass instabil FU Sun la fiecare 2 secunde nlocuire baterie br Sun la fiecare 2 secunde Eroare EEPROM EE Sun la fiecare 2 secunde Eroare Cod Icoan Eroare pornire BUS 01 Suprat...

Page 32: ...e nainte de nlocuirea bateriilor ATEN IE Pasul 1 nl tura i panoul frontal Pasul2 Deconecta icablurilebateriei Pasul 3 Scoate i cutia bateriei prin eliminarea celor 2 uruburi de pe panoul frontal Pasul...

Page 33: ...ta i toate bornele bateriei urm rind grafica de mai jos Procedura de asamblare a kit ului de baterii 6 1 Balder 1500 Pasul 1 ndep rta i benzile adezive Pasul 2 Conecta i toate bornele bateriei urm rin...

Page 34: ...Cauz posibil Solu ie Codul de eroare 28 p lp ie pe ecranul LCD i alarma sun continuu Tensiunea bateriei este prea mic sau nc rc torul este defect Contacta i unitatea de service Icoanele i iar codul d...

Page 35: ...blem Cauz posibil Solu ie Codul de eroare este afi at ca 01 02 03 04 11 12 13 sau 41 pe panoul LCD i alarma sun continuu O eroare intern a avut loc Exist dou posible rezultate 1 Sarcina este nc furniz...

Page 36: ...oned product was found in compliance with 2004 108 EC EMC Directive Also tested with the listed standards the above mentioned product was found in compliance with 2006 95 EC LVD Directive EN 62040 2 2...

Page 37: ......

Reviews: