background image

 

1.

 

ON/OFF Switch 

            This ON/OFF switch controls power to all of the       
outlets on the UPS. 

2.

 

AC Normal / On Battery / Boost Mode LED 
(Green) 

            Indicate the utility power is normal / UPS on battery 
or boost mode (flashing). 

3.

 

UPS Abnormal LED (Red) 

Indicate the UPS output overload / UPS charger   
Failure / Replace Battery. 

4. 

Battery Power & Surge Protection Outlets

 

The three outlets not only provide full time surge 
protection but also provide emergency   battery 
backup power during the utility power failure such 
as a blackout or brownout. 

5.

 

Surge Protection Outlets 

The three outlets provide full time protection from 
surge and spike. 
Plug your peripheral equipments that do not 
require power during the utility power failure. 
Such as printers, scanners, fax machines, or 
speakers. 

6.

 

Coaxial Surge Protection 

Provide protection for cable / satellite inputs. 

7.

 

USB Port 

Built-in USB port connects to your computer. 
Provide the automatic shutdown with software 
with USB cable to automatically save the files and 
shut down the equipments if the utility power is 
failure. Your personal computer can receive the 
status as utility power line, utility power failure, on 
battery and low battery by contact closure signals 
that are sent through the USB port. 

NOTE: 

This connection is optional; your UPS will operate 

normally without this connection

8. 

Outlet protection for network / internet

 

The RJ45 jacks can provide protection against 
surge and spikes on your internet line.

 

9.

 

Power Cord

 

Connect to the input utility power through the 
power cord. 

10.

 

Input Circuit Breaker 

 Protect against overload. 

11.

 

Battery Replacement cover 

Slide the cover off you can replace the battery. 
Please refer to the following   steps to replace the 
battery. 
a. Lay down the UPS and use the screwdriver to 
open the battery cover on the  bottom of the UPS. 

b. Grasp the tab attached to the battery and slide 
the battery out.

 

 

       

 

12.

 

 Walls Mount Holes 

 Use the wall mount holes that you can mount UPS 
to the wall. 

 

    

Audible / Visual Indicators 

 

 

 

 

 

 

 

 

 

 

 

 

Alarms

 

 

 UPS 
Status

 

ON 

AC Mode 

Blink 

Boost 
Mode 

ON 

Constant 

ON 

UPS / 

Battery 

fault 

Blink 

1 Beep at 

4 sec 

DC Mode 

Blink 

Beep 

Intermitte

ntly* 

Overload 

         *AC Mode 

2 beeps at 1 second for 105% and 2 beeps @ 0.5 seconds for 
130%. After 2 minutes, UPS will shutdown automatically. 

         *DC Mode 

2 beeps at 1 second for 105%. After 20 seconds, UPS will 
shutdown automatically. Or, immediately shutdown for 130 
 

Verification Instructions

 

 

Once you have received the UPS product, you should 
remove and inspect the product for shipping damage. If any 
damage is found, please notify the carrier and your dealer. 
You have to keep the shipping carton and the packing foam 
in case the product must be 
returned to the factory for service. 
 

SAFETY INSTRUCTIONS 

 

1.

 

Place the UPS indoors in an area that has adequate 
airflow and is free excessive dust. Do 

NOT 

allow the 

UPS to be exposed to moisture, rain, excessive heat or 
direct sunlight. 

2.

 

Use of the UPS product in life support applications 
where failure of this equipment can reasonably be 
expected to cause failure of life support equipment or 

Reviews: