to significantly affect its safety or effectiveness is 

NOT 

recommended. 

3.

 

Please always disconnect the input power cord from 
the wall outlet before replacing the battery. 

4.

 

Do 

NOT 

dispose of battery in a fire. The battery may 

explode. 

5.

 

Do 

NOT 

open or mutilate the battery. They contain an 

electrolyte that is toxic and harmful to the skin and 
eyes. 

6.

 

Proper disposal of battery is required. Please refer to 
your local laws/regulations regarding to battery 
disposal.

 

7.

 

Using tools with insulated handles to replace the 
battery to avoid personal injury. Due to energy hazard, 
please remove wrist watched and jewelry such as rings 
when replacing battery. 

Troubleshooting 

 

Symptom 

Possible 
Cause 

Action to Take 

UPS can not 
turn on. 

On/Off 
switch not 
pushed 
completely 

Press and hold the On/Off switch for 

sec. Or until you hear a beep sound. 

Battery 
voltage is 
too 
low. 

Call for service. 

UPS always at 
battery 
mode. 

Power cord 
loose. 

Re-plug the power cord firmly. 

Circuit 
breaker 
tripped. 

Remove some loads and reset circuit 
breaker. 

Line voltage 
too high 
or too low. 

Check input voltage. 

UPS is normal 
but the 
computer 
won’t turn on 

Computer 
input 
power cord 
is loose 
or not 
connected. 

Reconnect computer input power 
cord 

Connected 
equipments 
lose 
power while 
connected to 
the 
UPS. 

The “Battery 
Backup 
& Surge 
Protection” 
outlets are 
overload. 

Refer to the Symptom overload. 
Remove the non-critical loads and 
start 
the UPS again. 

The UPS has 
exhausted its 
available run 
time. 

The UPS will turn off when the 
battery 
has been depleted during the failure 
of 
utility power. Allow UPS to re-charge 
before continuing using of the UPS. 

The UPS will 

Ensure the equipment that you want 

turn off 
when the 
battery 
has been 
depleted 
during the 
failure of 
utility power. 
Allow UPS to 
re-charge 
before 
continuing 
using of the 
UPS. 

to 
stay powered during a failure of 
utility 
power is plugged into the “Battery 
Backup & Surge Protection” outlets. 

The UPS may 
be 
faulty. 

Call for service. 

 
 

     

Specification 

 

Model 

n’Joy Protector 801 

Power 

650VA / 325W 

Nominal Input Voltage 

230Vac 

Input Voltage Range 

172~272Vac 

Nominal Output Voltage 

230Vac 

Output Voltage Range at 
Line 

+18% ~ -15% 

Output Voltage Range at 
Line 

-40% 

Frequency 

50 / 60 Hz Auto detection 

Outlets 

6 Outlets (3 Battery Backup & 
Surge Protection; 3 Surge 

Protection only) 

Lighting / Surge 
Protection 

480 Joules 

Transfer Time to Battery 
/ AC 

< 4 ms 

Battery Type 

Sealed and leak proof 

maintenance free lead-acid 

battery 

Battery Specification 

12V/7AH x 1 

TYpical Backup Time 

10 ~ 15 min 

Internet Protection 

RJ45 (1 in / 1 out) 

Coaxial Surge Protection 

1 in / 1 out 

Communication Port 

USB 

Operation Temperature 

+32 ~ 104 (0 ~ 40) 

Operation Relative 
Humidity 

0 to 95% without 

condensation 

Storage Temperature 

+5 ~ 113 (-15 ~ 45) 

Net Weight 

13.9 lbs / 6.3 kg 

Dimensions (DxWxH) 

272x174x112mm 

Agency Approval 

CE 

         * Specification change without notice.

 