background image

 

RR40•20 Technical Manual 

CHARACTERISTICS

 

The  Duet  Rotobolt  is  an  Electronic  RotoBolt  Lock  with  a  manipulation-resistant  4-wheel 

mechanical combination override. It can be mounted in all four mounting directions.   The Basic 

Electronics feature a 6-digit Main code that can be changed by the user.   With the main code a 

secondary  code  can  be  activated  and  deleted.    If  a  valid  code  has  been  entered,  the  lock 

electronic removes the blocking for 3 seconds and the boltwork can be moved into OPEN position 

by pushing the bolt inside the lock case.   When moving the boltwork into LOCKED position the 

RotoBolt  automatically  secures.  Mechanical  openings  follow  standard  4-wheel  locks  operating 

procedures through entry integrated mechanical dial.

 

ENTRY UNITS

 

The Duet Rotobolt is compatible with the following NL LOCK Entry units (separate technical 

descriptions for Entry units are available). Entry unit cable hole on the safe door does not have to 

exceed 12 mm diameter 

 

RR40•20 Technical Manual rev. 170528 

 

 

© 2017 Lock Technology  Page 

!

 of 

!

1

4

Duet Series:              

DI20                                              DB20 

!

Duet RotoBolt

Important:  

Modifications to the lock (including 
lock bolt attachments) are not 
allowed, and will void the 
manufacturer’s warranty and 
Standards approvals. 

No through holes on the safe door 
are allowed within the lock body area. 

Lock body area should be protected 
against destructive attacks

Summary of Contents for Duet RotoBolt RR40

Page 1: ...ED position the RotoBolt automatically secures Mechanical openings follow standard 4 wheel locks operating procedures through entry integrated mechanical dial ENTRY UNITS The Duet Rotobolt is compatible with the following NL LOCK Entry units separate technical descriptions for Entry units are available Entry unit cable hole on the safe door does not have to exceed 12 mm diameter RR40 20 Technical ...

Page 2: ... test the electronics Function 5 Functional Test Enter code i e 1 2 3 4 5 6 The lock emits a double signal for the correct code Turn boltwork handle towards OPEN position The bolt rotates into the housing Bolt must move freely Turn handle towards Locked position The lock bolt must fully extend and secure Make sure there is an air space on all sides of the lock bolt when the safe s boltwork is full...

Page 3: ...ng the dial in and release the buSon Step 5 Dial the combina9on by turning the dial LEFT and pass 50 four 9mes and stop exactly on 50 the fiCh 9me on the opening index Turn RIGHT and stop on 92 Then turn the SAFE HANDLE to open the lock Note Due to installa9on tolerances it is possible that the code may have shiCed up or down two numbers This shiCing is normal and will be eliminated once the code i...

Page 4: ... is entered turn dial to the right and stop on 92 and then turn the safe handle to open the lock RR40 20 Technical Manual rev 170528 2017 Lock Technology Page of 4 4 Changing Instructions 071717 Page 1 of 1 Using the changing index turn the dial to the le3 and pass 50 five 5 mes and then stop exactly on 50 the sixth me Insert the change key into the hole marked with the arrow Make sure that the cha...