InterLynx/TS User’s Manual_________________________________________________________________
1-2
Refer to figure 1-1 above to reference the following steps:
1)
Connect the CAT 5 cable to the Ethernet interface on the back on the InterLynx/TS.
2)
Connect the other end of the CAT 5 cable to the Internet connection device (i.e. router, cable modem, etc.).
3)
Set the voltage switch to the appropriate setting for your area.
An improper setting will damage the power supply and
may cause personal injury.
4)
Connect the female end of the power cord into the AC power connector on the back of the InterLynx/TS.
5)
Plug the male end of the power cord into a wall outlet.
Section B
Connect other network devices such as terminals or hubs to the Ethernet interfaces (RJ45 Sockets) on the front of the
InterLynx/TS unit using CAT 5 lines.
Front panel controls for the InterLynx/TS firewall
Troubleshooting
Diagnostic LED indicators
LED
State
Indication
Power
On ( green )
Unit is powered on
Flash
On/Flashing ( amber )
Activity on Flash card
LAN
On ( amber )
Internal Network is functioning properly
FDX/Col
On ( amber )
Off
Flashing ( amber )
Port is operating in full-duplex mode
Port is operating in half-duplex mode
Port has detected a collision on this port
Act/Link
On ( green )
Off
Flashing ( green )
Port has a valid network connection
Port has not established any network connection
Port is transmitting/receiving data
100m
On
Off
Port is operating at 100mb
Port is operating at 10mb
Symptom:
Link indicator does not light up after making a connection.
Cause:
Network interface or network cable is defective.
Solution:
Verify that the switch and attached devices are powered on. Be sure the cable is correctly
plugged into both the switch and corresponding device. Verify that the proper cable type is used
and its length does not exceed specified limits. Each twisted-pair cable should not exceed 100m
(328 ft.). Check the adapter on the attached device and cable connections for possible defects.