INSTALLATION 

 
 

HARDWARE 

 

Before you proceed with the installation of the board, make sure that the backplane technology 
matches with the board technology (power supply, busses, etc ...). 

CompactPCI headers located on the backplane are fragile 

 

Ensure that the board is properly inserted into the board guide and connectors are aligned with 
its related slot. If there is any resistance, do not use force to engage the board

 

 

 

Installation:

  

When the system is up and running, it is important to install the Rear Access I/O Module first 
then complete with the installation of the Front Module. 

Removal:

  

When the system is up and running, it is important to remove the Front Module first then 
complete with the removal of the Rear Access I/O Module. 

Caution:

  

The Rear Access I/O Module must not be installed or removed as long as Front Module is 
present in the system.  

 

For complete information on hardware installation, refer to the User’s Guide. 

 
 

SOFTWARE 

For complete information on software installation, refer to the User’s Guide. 

 
 
 

KNOWS BUGS  

None at this time. 

 
 

MAKING CONNECTIONS 

 
 

DS3 CONNECTION 

The physical media consists of two 75-ohm coaxial cable links (with RJ-59 BNC connectors), one 
for each direction of transmission. 
Insertion loss and phase characteristics for cables are as follows: 
 

 

 

 

 

For complete specifications, please refer to ANSI T1.102-1993. 

 
 

RS-232 CONNECTION 

The RS-232 interface be connected to an RS-232 terminal or a PC running a terminal emulation 
software. The interface is set as follows: 57600 bauds ; 8 data bits  ; 1 stop bit ;  No parity. 
The RS-232 cable must be a shielded RS-232 Null-Modem cable with a female DB9 connector. 

NOTE

: The serial interface is for debug purposes only. 

 
 

ETHERNET CONNECTION 

The Ethernet connection must be made of an unshielded twisted pair (UTP) cable and a standard 
RJ-45 connector. 
The Ethernet interface is specified as follows: 10Mb/s ; Half-duplex. 

NOTE

: The Ethernet interface is for debug and maintenance purposes only. 

 

REPAIRS 

Any repair to this board must be carried out by NMS. If you suspect the equipment is malfunctioning, check
the appropriate part of the User’s Guide to make sure that all installation procedures have been followed
correctly. If checking the installation procedures does not locate the problem, contact your field service
representative or our home office. 

For return of material, refer to the RMA section. 

 

 

RMA –Return Material Authorization 

Check to see if the problem is due to a mistake or oversight in the installation process. 

Contact our Technical Services at (450) 676-2977 to confirm that it is a board problem. 

While observing correct static-safe handling procedures, disconnect all cables and remove the 
board from the chassis. While the board is out, make a note of the serial number (located on a label 
on the board). 

Contact the RMA coordinator at (450) 676-2977. Give the board’s serial number and a brief 
description of the problem. The RMA coordinator will give you an RMA number and an estimated 
return date. 

Pack the board in an anti-static shipping material. Include a printout of the brief description of the 
problem. 

Ship the board to NMS at the following address. NMS is not responsible for risk of loss or damage 
in transit. 