19
18
Ex9ML residual current protection circuit breaker/residual current protection module
Ex9MSD switch disconnector
Ex9ML
Product
code
Ex9ML:
residual current
protection
circuit breaker/
residual current
protection
module
1: 160A
2: 250A
3: 400/630A
Frame size
code
2
3P
Default
ALT
250
RCD2
Rated
current (A)
Code of residual
current type
Code of special
demand
Pole number
code
Code of residual
operating current
Default: AC
type
A: A type
Default: no
special demand
ALT: release
upon leakage
alarm
ALNT: does not
release upon
leakage alarm
3P
4P4T:
protected
N pole,
operable
Model Selection example:
Ex9ML2N SU20L 250 3P A RCD2 ALT refers to an
Ex9ML2 series 3 pole moulded case circuit breaker with frame size of 250A, breaking capacity
of 50kA and rated current of 250A, providing basic type electronic power distribution protection. It is equipped with type A residual current protection
module, with leakage alarm release function and residual current adjustment range of 0.05A-0.2A-0.5A-2A.
Model Selection example:
Ex9M6SD AC 1250 3P MOD AC230V refers to an
Ex9M6SD series AC 3 pole motor-driven operating switch disconnector with frame size of 1600A,
operating current of 1250A, and control voltage of AC 230V.
Accessories of Ex9M series products
Short name of accessories
Frame size code
Explanations
Explanations
Pole number code
Special demand code
SHT
Please see table
below
Please see table
below
Default: normal
M: low power consumption
Not needed if no
operating voltage
3P: three poles
4P: four poles
No code if no special
demand;
Develop code according
to special demand.
Reference table for accessory type
1)
Name
Abbreviation
Ex9M1
Ex9M2
Ex9M3
Ex9M4
Ex9M5
Ex9M6
Auxiliary contact
AX
AX21
Alarm contact
AL
AL21
Shunt release
SHT
2)
SHT 21/SHT 21M
SHT 22/SHT 22M
SHT 24/SHT 24M
SHT 26
Undervoltage release
UVT
UVT 21
UVT 22
UVT 24
UVT 26
Closing electromagnet
XF
3)
—
—
—
—
—
XF 26
Direct rotary handle
RHD
RHD 21
RHD 22
RHD 23
RHD 24
—
Extended rotary handle
ERH
ERH 21
ERH 22
ERH 23
ERH 24
ERH 26
Long handle
LHD
—
—
—
—
—
LHD26
Motor-driven operating mechanism MOD
MOD 21
MOD 22
MOD 23
MOD 24
MOD 26
Handle locking device
KLK
KLK 21
KLK 22
KLK 23
—
—
Mechanical interlock
MIT
MIT 21
MIT 22
MIT 23
MIT 24
—
Short terminal cover
TCV
TCV 21
TCV 22
TCV 23
TCV 24
—
Long terminal cover
TCE
TCE 21
TCE 22
TCE 23
TCE 24
—
Front connection plate
JP
JP 21
JP 22
JP 23
—
JP 26
Rear connection plate
RCP
RCP 21
RCP 22
RCP 23
RCP 24
—
Draw-out base
DOB
—
—
DOB 23
DOB 24
—
Plug-in base
PIA
PIA 21
PIA 22
PIA 23
—
—
Cable connector
MC
MC 21
MC 22
MC 23
MC 24
MC 26 W3
MC 26 W4
Rail adapter
DRA
DRA 21
DRA 22
—
—
—
Communication module
COM
COM 22 (for Ex9M SU electronic series)
Battery box
BAB
—
BAB 22
Interphase barrier
PHS
PHS 21
PHS 22
PHS 23
PHS 24
PHS 26
Model Selection example:
SHT 22 AC110V
: Order a shunt release for product with frame size of Ex9M2 and Ex9M3, with rated control voltage of AC 110V;
RHD 23
: Order a direct rotary handle for Ex9M3 product.
Similar for others.
— None
SHT/UVT rated control voltage
MOD rated control voltage
AC48V DC24V
AC110V DC48V
AC220V-240V DC110-120V
AC380V-415V DC220V
AC110V DC24V
AC220-240V DC110-120V
AC380V-415V DC220V
Model Selection and Ordering Information
Model Selection and Ordering Information
Note:
1)
1P product only provides handle locking device, 2P product provides internal accessories (including shunt release, undervoltage release,
auxiliary contact) and external accessories (including handle locking device, front/rear connection plate), other accessories are not included.
2)
There are two types of shunt release available: normal type and low power consumption type (plus M behind frame size code);
3)
Only available for Ex9M6 MOD motor-driven version circuit breaker.
N
SU20L
Breaking
capacity code
Release
code
S: 36kA
N: 50kA
Q: 70kA
H: 100kA
P: 150kA
TM: thermo-magnetic
power distribution
protection
SU20L: basic type
electronic power
distribution protection
SU20S: standard
type electronic power
distribution protection
M: electromagnetic
motor protection
SU20LM: basic type
electronic motor
protection
SU20SM: standard
type electronic motor
protection
See the current
specifications
of TM/SU20L/
SU20S/M/
SU20LM/
SU20SM
AC circuit
breakers with
corresponding
frame size.
RCD1: 0.03-0.1-0.3-1A
adjustable (applicable
to Ex9ML1/2/3)
RCD2: 0.05-0.2-0.5-2A
adjustable (applicable
to Ex9ML1/2)
RCD3: 0.05-0.2-0.5-1A
adjustable (applicable
to Ex9ML3)
RCD4: 0.1-0.3-1-2A
adjustable (applicable
to Ex9ML3)
Ex9M
Product code
3: 400A
250A: default
4: 630A
400A: default
5: 800A
630A: default
6: 1600A
800A,1000A
1250A,1600A
800A: default
Frame size
code
2: 250A
1: 160A
160A: default
6
SD
AC230
AC
1250
3P
MOD
Function
code
Application
category code
Operating
current code
Control
voltage
2)
Pole number
code
1)
Operating
rules
2)
SD:
disconnecting
switch
AC: alternate
current
DC: direct
current
1P/2P/3P/4P
Default: manual
version
MOD: motor-
driven version
Note:
1)
1P/2P is only applicable to products with frame size of Ex9M1SD and Ex9M2SD
2)
Only applicable to products with frame size of Ex9M6SD.
22
M
AC110V
3P
OTHER
Note:
The residual current protection module does not have code for breaking capacity, release and rated current, these can be offered separately;
electronic protection is not available for product with frame size of 160A, please contact Noark for details.
AC230V
AC400V
DC110V