38
Note:
If you wish to carry the device in a bag/suitcase,
please turn it off for safety reasons. Your device has a
ten (10) seconds cut off system for protection of the at-
omizer and the battery from prolonged use.
Screen Protection
With the device powered on, simultaneously press the
fire and (+) button to enter SCREEN mode. With +,- but-
tons you can choose the time of the screen protection.
Screen orientation:
With the device powered off, simultaneously press the
+,- buttons to change the screen orientation by 180°.
MALFUNCTION AND PROTECTION
INDICATIONS
Over 10s protection:
Fire button is pressed over ten
(10) seconds. Device cuts power automatically.
Atomizer Short-circuit Protection:
Atomizer coil head
is short circuited. Replace with a new one or check the
atomizer.
Low power Alert:
Battery volts are below 3.3V. Please
charge the device.
Product manual