background image

5

Colloid Storage

Please follow these procedures when storing
used material that will be re-melted.

1. After removing the colloid from the 

duplicating flask, rinse with water to remove
any foreign material clinging to the colloid.
Pieces of gypsum or investment that remain
in the colloid can permanently damage the
tank and/or stirrer, as they will be dragged
around inside the tank during the cook-down
cycle.

2. Gently shake-off excess water.

3. Store colloid in a clean, covered 

container. Keep container covered so 
moisture is not lost.

4. When ready to cook-down, cut colloid

molds in quarters, then load duplicator.

5. If re-melted colloid is difficult to 

dispense due to high viscosity, add small
amounts of water until the viscosity is
reduced.

Changing Duplicating Material

When the tank is virtually empty, press 
the red POWER button on the front panel to 
turn-off the duplicator. To remove the colloid
at the very bottom of the tank, simply allow
it to cool then peel it out.  

Preventive Maintenance & Cleaning

1. Clean Colloid-Saver 3.5 duplicator 

approximately once a month or when 
new duplicating material is added. Your 
frequency of cleaning may vary with usage.
Scrub inside wall of tank and cover assembly
with a non-abrasive pot scrubber.

2. Inspect stirrer for wear and distortion.

Clean with non-abrasive pot scrubber. 

3. Remove back panel and inspect the

bearing. If any colloid is leaking from this
area, the bearing must be replaced. 

4. Be very careful not to spill liquids on

the duplicator! Liquids can damage the 
control panel and circuit boards. If a spill
occurs, unplug the duplicator immediately
and clean thoroughly.

5. Clean fan air filter regularly to maintain

proper air flow.

Calibration

Calibration of the Colloid-Saver 3.5 
duplicator is not necessary. The computer
controller is self-calibrating.

Continuous Dispensing (Emptying)

The Colloid-Saver 3.5 duplicator 
can be used to fill flasks in a continuous 
line using the optional Dispensing 
Extender shown in 

(Figure D)

.

(Figure D)

Dispensing 
Extender

Summary of Contents for Ticonium Colloid-Saver 3.5

Page 1: ...for precision temperature control SmartCycle stirring cycle activated only when needed minimizing colloid breakdown High volume no drip no clog dispensing nozzle Pre set programs for virtually any col...

Page 2: ...ty If you have any questions regarding CMP s quality line of dental laboratory equipment and supplies please call toll free 800 833 2343 or 518 434 3147 Fax 518 434 1288 between the hours of 8 00 AM a...

Page 3: ...ed as the Colloid Saver 3 5 duplicator draws about 12 amps at 115 volts As with any electrical device take extra care when handling liquids around electrical connections to avoid accidental shock It i...

Page 4: ...ke sure to add any liquid that may be in the bottom of colloid container The liquid contains ingredients which extend the life of the colloid Replace top cover and rotate it counter clockwise to engag...

Page 5: ...at the very bottom of the tank simply allow it to cool then peel it out Preventive Maintenance Cleaning 1 Clean Colloid Saver 3 5 duplicator approximately once a month or when new duplicating material...

Page 6: ...rofile settings below To select a specific profile the duplicator must be in Standby Mode power on but no heating lights illu minated Press the SET button twice The display will show the first option...

Page 7: ...life VII Troubleshooting 1 Colloid Saver 3 5 duplicator will not turn on A Check wall outlet for power B Check if power cord is connected to duplicator C Check if the main power supply is turned to th...

Page 8: ...P37 2 Precision Laser 40811P48 3 LED Light 40811P38 4 Power Entry Module 40811P20 5 Cover Lock 40811P44 6 Poly Cover 40811P1 7 Cover Interlock 40811P45 8 Cover Handle 40811P43 9 Power Cord Assembly 40...

Page 9: ...ART NUMBER 1 USB Port Connector 40811P39 2 1 Amp Motor Circuit Breaker 65383P7 3 15 Amp Main Breaker 65383P6 4 Power Entry Module 40811P20 5 Rubber Feet 40811P19 6 Knob 40811P2 7 Valve Body 40811P7 8...

Page 10: ...ide Heater 40811P33 5 Controller 40811P34 6 Drawer Slide 40811P12 7 Solid State Relay 41984P18 8 Handle 40811P26 9 2 Pin Connector 40811P51 10 8 Pin Connector X2 40811P50 11 14 Pin Terminal Block 4081...

Page 11: ...lar 40811P35 6 Motor 40811P31 7 Gearhead 40811P31A 8 Power Supply 40811P40 9 Thermistors 120C 40811P28 10 Tank Assembly 40811G3 11 Bottom Heater 4081132 12 Cover Interlock Bracket 40811P46 13 Panel Sa...

Page 12: ...Tank Stirrer ITEM DESCRIPTION PART NUMBER 1 Thermocouple K Type 10980 2 Main Shaft 40811P13 3 Bearing 40811P29 4 Seal 40811P41 5 Stirrer Assembly 40811G2 6 Stirrer Knob 40811P18 4 3 2 5 1 Inside View...

Page 13: ...13 Accessories ITEM DESCRIPTION PART NUMBER 1 Dispensing Extender 40811P58 1...

Page 14: ...Street Albany New York 12207 USA Toll Free 800 833 2343 USA 518 434 3147 Fax 518 434 1288 USA Email info cmpindustries com Export Email export cmpindustries com Website www cmpindustries com Form 4081...