Use and Maintenance Manual model “A8 - A10 V/C ROUND/TOP”
26
ENGLISH
Edit the data highlighted using the keys
Confirm the data changed using the key
To return to the STAND-BY screen, use the
key , repeating the operation multiple times.
OK
11.8 FIRMWARE VERSION
To view the version of the firmware installed for
the appliance model supplied, follow the procedure
in this paragraph. This function is useful for the support
centre to control availability of the new updates to
install on the product, if necessary.
OPERATING PROCEDURE:
MENU >> SET USER >> SETTINGS >> FW VERSION
Access the menu by pressing key
Scroll the items to SET USER with the key
Access the menu by pressing key
Scroll the items to SETTINGS with the key
Access the menu by pressing key
Scroll the items to FIRMWARE VERSION with the key
Access the function by pressing key
OK
OK
OK
OK
To return to the STAND-BY screen, use the
key , repeating the operation multiple times.
When you pass from one screen to another, you
display the following screen for a few seconds:
GENERAL INFORMATION NOTE:
This screen indicates the handheld device is trying
to communicate with the appliance, a useful
operation to recover information to display to the
end user.
If communication is absent, the writing FIELD followed
by a number appears. In this case, simply approach
the appliance to re-establish
communication.
12 CHANNEL
(where planned)
The products of the range equipped with channel-
ling
are in two types, single duct channelling or double
duct channelling. It can be disabled, manually set
or auto-management enabled based on the tem-
perature gradient you want to obtain in the room
where channelling is installed.
12.1 SET SINGLE CHANNELLING
In this paragraph, the system is detailed to enable/
disable and set in manual the
ventilation speed assigned to channelling.
Furthermore, the possibility is set to enable the
automatic management function of channelling,
linked to setting of the ambient temperature you
want to obtain in the room.
1
2
1
2
11.9 ANTICONDENSATION
(exhaust fumes temperature)
This function ensures that the temperature
of exhaust gases remains higher than condensing
temperature.
OPERATING PROCEDURE::
MENU’ >> SET USER >> SETTINGS >> ANTICONDENSATION
Access the menu by pressing key
Scroll the items to SET USER with the key
Access the menu by pressing key
OK
OK
The function results in a slight increase of pellet
consumption to remedy this condition.
The causes of condensation can be related to the
installation but above all to the yield of the pellets
and its size.
Scroll the items to SETTINGS with the key
Access the menu by pressing key
Scroll the items to ANTICONDENSA with the key
Activate / Deactivate function by pressing
of the key
OK
OK
To return to the STAND-BY screen, use the
key , repeating the operation multiple times.