Use and Maintenance Manual model “H14 V SHAPE”
35
ENGLISH
ENGLISH
FASE
DESCRIZIONE
The appliance signals a malfunc-
tion of the sensor controlling correct
combustion. For safety purposes,
while waiting for the technician, the
appliance is set to saving mode.
The maximum smoke temperature
threshold has been reached; the
appliance for a period sets to saving
mode with ventilation at maximum
power to cool the body.
If the quantity of pellets is high for
the power of the machine. In P/E
mix, reduce the pellet load working
on the % (see specific
paragraph)
The appliance signals a malfunction
of the probe detecting the flame.
For safety purposes, while waiting
for technical intervention, the appli-
ance sets to saving mode.
S.PRESSIONE GUASTO
FASE
DESCRIZIONE
The anomaly is presented when
the user opens the door or ash pan
or pellet door; at this point, pellet
loading inside the brazier stops and
the electronics emit an acoustic sig-
nal. The user, to return to correct op-
eration, must
close the doors. If this
operation is not carried out, the
product signals an alarm.
Anomaly of the probe controlling
the temperature of the discharge
smoke, contact the authorised tech-
nician to solve the fault.
Anomaly to the probe monitoring
the system return H
2
O temperature:
contact the authorized technician
to resolve the malfunction.
Anomaly to the probe monitoring
the water temperature in the DHW
storage tank (Boiler): please, con-
tact an authorized technician to
solve the problem.
Anomaly to the upstram probe mo-
nitoring the water temperature in the
technical water storage tank (hot water
tank): please contact an authorized
technician to solve the problem.
17 ANOMALIES OVERVIEW
HOT FUMI
CARICO ECCESSIVO
S.FIAMMA GUASTA
18 DESCRIPTION OF ALARMS
ALARM CODE
REASON
01
BLACK OUT
No power during the work phase
SOLUTION
Press the switch off key and repeat
switch on of the appliance
If the problem persists, contact the Support
Service.
ALARM CODE
REASON
02
NO
SWITCH ON
The pellet tank is empty.
Calibration of the pellets and suction during
the start-up phase inadequate.
Ignition resistor faulty or out of position
SOLUTION
Check there are pellets in the
tank. If necessary, load.
If the problem persists, contact the Support
Service
ALARM CODE
REASON
03
PELLETS FINISHED
The pellet tank is empty.
The gearmotor is not loading pellets
Lack of pellets loading
SOLUTION
Check there are pellets in the
tank. If necessary, load
Empty the tank to check that
there are no objects inside it.
Adjust, by increasing the load of pellets, from
“P/E MIX”
If the problem persists, contact the Support
Service
The anomalies, differing from alarms, are signals
which automatically reset, once the cause that
generated them has been eliminated.
Furthermore, the signalling does not cause the ap-
pliance to switch off, guaranteeing however
heating.
Some anomalies, to be resolved, need technical in-
tervention by authorised
staff. Despite the appliance continuing to work, the
user must ensure the
problem is resolved.
Negligence causes the product
to malfunction
.