Use and maintenance manual model “UNICA 10 V/C” - WOOD

ENGLISH

20 

image, taking care to place the ignition materials 

on top of the wood logs in the hearth.

After that, as soon as Unica detects the increase 

in temperature, it will activate the smoke engine 

for smart combustion and room heating with the 

same logic of cold ignition by pellets.

9.9  OPERATION WITHOUT ELECTRICITY

Unica has been designed to work with wood even 

without electricity. If a blackout occurred while 

Unica was already working in wood mode, the 

combustion will not change. On the other hand, 

if we decide to disconnect the stove from the 

power supply and use it as a normal WOOD stove, 

we will have to act differently.

IN CASE OF ELECTRICAL FAILURE

In the event of a sudden loss of electrical power 

(which powers the motors, fans, safety devices, 

combustion air management system, etc.), the 

safety valve, held closed by an electromagnet, 

will open to facilitate the expulsion of smoke from 

the hearth.

In  the  figure  below  you  can  see  the  rod  raised, 

showing the opening of the safety hatch (BYPASS).

SAFETY HATCH: LIFTED SHAFT

 - BYPASS

HANDLE FOR OPENING/

CLOSING THE WOOD 

COMBUSTION AIR

The opening of the BYPASS system is also controlled 

by a micro-switch which, when the power returns, 

warns via the remote control of the need to lower 

the lever, bringing it back to its initial position (thus 

closing the by-pass).

Without electricity, Unica requires the combustion 

air valve to be opened manually, using the handle 

located next to the BYPASS rod, TO ADJUST AIR 

SUPPLY FOR COMBUSTION.

The handle must be inserted into the hole at the 

base of the right side, as shown in the following 

figures,  and  must  be  used  when  loading  new 

logs to stoke the flame as soon as possible; after 

this operation, the handle can be closed safely, 

step by step, as the combustion air management 

system was already in the ideal position for burning 

the wood logs.

fully closed wood 

primary air

fully open wood 

primary air

The manual valve for the wood combustion air 

is also equipped with a micro switch to notify via 

remote control it is open when the power returns.

Both the BYPASS valve and the MANUAL WOOD 

PRIMARY AIR valve must be 

CLOSED

 in order to 

restore normal operation with electricity. 

ALWAYS 

close the PRIMARY AIR valve first, then close the 

safety hatch by means of the rod

. If both valves 

are open, the smoke motor WILL NOT START for 

safety reasons, i.e., because the smoke circuit is 

open, like the duct fan.

IN CASE OF LACK OF ELECTRICITY

To use Unica as a normal wood-burning stove 

without electricity, load and light the wood as 

explained in paragraph 9.8 and use the handle 

for the primary combustion air of the wood as 

illustrated in the previous paragraph.

Unica will work like a normal wood-burning stove 

Summary of Contents for UNICA 10 V/C

Page 1: ...EN Installation use and maintenance manual WOOD UNICA 10 V C...

Page 2: ...uctions manual can be reproduced or transmitted with any electronic or mechanical device including photocopying recording or any other saving system for any purpose other than the exclusive personal u...

Page 3: ...7 1 RECEIVER 15 7 2 KEYS 16 7 3 DISPLAY 16 7 4 FLAT BATTERIES 16 7 5 ICON LIST WOOD 17 7 6 POWER MANAGEMENT 17 8 NAVIGATION MENU 17 9 START UP INSTRUCTIONS 17 9 1 DATE AND HOUR SETTINGS 17 9 2 ROOM PR...

Page 4: ...indicated in this manual prompt execution of extraordinary maintenance if necessary malfunctioning activity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The...

Page 5: ...ng faulty due to negligence or careless use wrong maintenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance f...

Page 6: ...the presence of forced ventilation or in premises which can go into negative pressure compared to outside 2 WOOD RECOMMENDED FEATURES For its products the Manufacturer recommends using class A1 or A1...

Page 7: ...ostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary for installation of the hermetic appliances that take air directly from outside Check and comply with the ventilation...

Page 8: ...ailable directly on the chimney flue plate 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following features the smoke outlet section must be at least double the inner section...

Page 9: ...is the case with concrete bricks etc wood composite materials etc In both cases make sure the passage for the flue pipe through the slab and the roof is wide enough to allow suitable safety distance 5...

Page 10: ...he RESY standards and wooden pallets All packaging materials can be re used for similar use or if necessary disposed of as urban waste in compliance with legislation in force Remove the strap binding...

Page 11: ...ould be subjected in the event of the opening of the safety bypass hatch Reassemble all the parts following the instructions in reverse WARNING THE SECTION OF THE EXHAUST PIPE MUST WITHSTAND TEMPERATU...

Page 12: ...f the outer thermostat function refer to the specific chapter in the following pages of this manual It is compulsory for the system to be grounded and have a differential switch in compliance with leg...

Page 13: ...0 S MATERIA PRIMA RAW MATERIAL A A B B C C D D E E F F 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 TUTTI GLI SVILUPPI FORNITI IN FORMATO DXF SONO TEORICI IL PARTICOLARE REALIZZATO DEVE ESSERE CONFORME AL DISEGNO...

Page 14: ...rolonged not use of command risk of oxidation and liquid leakage Nobis srl declares that the type of Handheld radio device complies with Directive 2014 53 EU The full text of the EU declaration of con...

Page 15: ...ust be enabled to allow the control unit to detect the presence of the external thermostat from the USER SETTINGS menu see the paragraph ENABLE EXTERNAL THERMOSTAT Enabling the external thermostat wil...

Page 16: ...nds of inactivity the remote control display blacks out and switches to SLEEP mode maintaining the remote connection with the appliance Press to reactivate it This Icon indicates the appliance status...

Page 17: ...led optional and enabled The menu is useful when you want to adjust the operating power to restart the appliance in pellet mode while Unica is running with wood 8 NAVIGATION MENU See the corresponding...

Page 18: ...From the STAND BY screen press to activate power modification Values range from 1 to 3 They are represented by black boxes visible below room temperature Make changes by pressing Confirm the new setti...

Page 19: ...ch subsequent load of wood the HOLD mode will be activated automatically This will maximize efficiency while minimizing emissions to the environment 9 7 COLD START Un Thanks to its flexibility Unica a...

Page 20: ...he need to lower the lever bringing it back to its initial position thus closing the by pass Without electricity Unica requires the combustion air valve to be opened manually using the handle located...

Page 21: ...th the only difference that it does not have 7 power levels but 3 plus PS which automatically follows the power set via remote control For further information see the same paragraph in the pellet mode...

Page 22: ...rating anomaly press OK to display more details The stove has detected an alarm condition press OK to view more details Note by resolving the condition causing the alarm Unica will continue to operate...

Page 23: ...ediately stop Unica in case of operation in pellet mode as for all the other Nobis products belonging to the pellet range Black Out with opening of the bypass hatch Safety thermal switch open door Pel...

Page 24: ...SE SAFETY VACUUM SWITCH FRONT VENTILATION K J LAPTOP CONNECTION technical support only USB CONNECTION technical support only REMOTE CONTROL EMERGENCY CABLE APPLIANCE SWITCH ON REMOTE UNIT SELECTION KE...

Page 25: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 25 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Page 26: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 26 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Page 27: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 27 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Page 28: ...o 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0031N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Reviews: