DESCRIPTION
The appliance detects fire in the
combustion chamber.
Until the temperature and fuel control
cycles have been carried out, the
display will not change.
The appliance has completed the
control PHASE, has verified the correct
ignition of the wood logs and switches to
"hold mode".
Room temperature has been reached as
per settings.
The ideal minimum temperature has been
reached in the combustion chamber.
It is now possible to add more firewood
(WOOD ALERT).
The device is in the shutdown phase and
the cooling phase is not yet complete.
The device is in OFF state and all motors
are disabled.
14 FUNCTION LIST
See the corresponding paragraph in the PELLET
manual.
15 SIGNAL LIST
Here is a list of those signals which are different
from pellet mode only. For more details, see the
same paragraph in the PELLET MODE manual.
PHASE
DESCRIPTION
The stove has detected an operating
anomaly: press
OK
to display more
details.
SWITCH TO
WOOD
MODE
PHASE
DESCRIPTION
The stove has detected an operating
anomaly: press
OK
to display more
details.
The stove has detected an alarm
condition: press
OK
to view more
details.
Note: by resolving the condition
causing the alarm, Unica will continue
to operate.
The MAXIMUM service hours
threshold has been reached.
It is recommended to request
extraordinary maintenance of the
appliance by authorized personnel.
16 ANOMALY LIST
PHASE
DESCRIPTION
The stove has detected an operating
anomaly: press
OK
to display more
details.
The user has opened the stove door.
Carry out loading operation within 60
seconds to prevent the stove from
triggering an alarm.
The stove has detected an operating
anomaly: press
OK
to display more
details.
The device signals a blocking of the
safety thermal switch. When Unica
switches off in wood mode, alarm 07
will be displayed and you will have to
follow the instructions indicated in the
alarms chapter of the pellet mode
manual.
Anomalies, unlike alarms, are signals that
automatically reset once the cause that generated
them has been resolved. Such notifications, unlike
alarms, do not turn off the machine.
To resolve some anomalies, technical intervention
by authorized personnel is necessary. Although
the device continues to work, users should take
care to contact the local technical support