background image

Use and maintenance manual model “UNICA 10 V/C” - WOOD

ENGLISH

1 INTRODUCTION 

The product by Nobis  was designed and 

manufactured in compliance with the reference 

standards for the manufacturing products 

(EN13240 wood stoves, EN14785 pellet appliances, 

EN13229 fireplaces/inserts for wood, EN12815 wood 

stoves), with high quality materials. The products 

also comply with the essential requirements of 

the  Directive  2014/35/EU  (Low  Voltage)  and 

the  Directive  2014/30/EU  (Electromagnetic 

Compatibility).

The printing, translation and reproduction, even 

partial, of this manual is intended as binding 

by the manufacturer's authorisation and the 

content of working logic and explanatory figures 

is considered not be be disclosed.

Always consult the authorised technicians if in 

doubt  and/or  confused  by  operation  of  the  the 

product.

The manufacturer reserves the right to make 

changes  to  specifications  and  technical  and/

or  working  features  of  the  product  at  any  time 

without prior warning.

1.1 SYMBOLS

Nel The following manual contains symbols which 

highlight the importance of particular descriptions 

or concepts;

INFORMATION

: Compliance with the specifications 

guarantees correct operation of the product.

ATTENTION

: Symbol used to identify particularly 

important information

DANGER

: The presence of this symbol indicates 

utmost attention is required, to guarantee user 

and product safety.

1.2

 

INTENDED USE

The  product  in  this  manual,  is  a  fireplace  for 

domestic heating, feed by automatic loading 

and exclusively with wood pellets.

The product was designed and manufactured to 

work in safety if the following conditions occur:

• installation by specialist staff according to the 

specific reference standards;

• use within the limits declared on the product data 

sheet and in this manual;

• compliance with technical procedures described 

in the manual;

• carrying out routine maintenance within the times 

and methods indicated in this manual;

• prompt execution of extraordinary maintenance 

if necessary (malfunctioning);

• activity and maintenance of safety devices (do 

not remove or bypass this devices).

1.3

 

IMPROPER USE

The product must be intended for the use for 

which it was expressly designed; for any other use, 

the manufacturer cannot 

be held in any way liable for damage caused to 

people, animals or property. 

Improper use is intended as:

• use of the product as an incinerator;

• use of the product with fuel other than wood 

pellets with a diameter of 6 mm;

• use of the product with liquid fuel;

• 

use of the product with the fire door open and/

or glass broken and/or ash pan removed and/or 

pellet tank open.

Any other use of the appliance other than that 

planned must be authorised in advance in writing 

by the manufacturer.

Furthermore, the manufacturer cannot be held in 

any way liable for errors in installation, adjustment 

or maintenance of the product.

1.4

 

IMPORTANCE OF THE MANUAL

This manual has the purpose of providing essential 

rules for correct installation, use and maintenance 

of the product.

PRESERVATION: Keep the manual in a place that is 

easy and quick to find;

DETERIORATION OR LOSS: Consult the official site 

to download the manual;

PRODUCT TRANSFER: In the event of sale between 

private individuals of the product, the owner is 

obliged to deliver the product with the following 

manual.

1.5  GENERAL SAFETY WARNINGS

Non-compliance with the provisions of this manual 

can cause damage to people, animals and 

property.

• Installation, testing of the system, functionality 

testing and initial calibration of the product must 

only  be  carried  out  by  qualified  and  authorised 

staff.

• The product must be connected to a single 

chimney  flue  that  guarantees  the  draught 

declared by the manufacturer and which 

complies with the installation standards outlined in 

the assembly location of the product.

• The premises where the product is installed must 

be adequately ventilated (air intake).

• Do not touch the hot surfaces without adequate 

protective equipment, to avoid burns.

• When in operation, the external surfaces reach 

Summary of Contents for UNICA 10 V/C

Page 1: ...EN Installation use and maintenance manual WOOD UNICA 10 V C...

Page 2: ...uctions manual can be reproduced or transmitted with any electronic or mechanical device including photocopying recording or any other saving system for any purpose other than the exclusive personal u...

Page 3: ...7 1 RECEIVER 15 7 2 KEYS 16 7 3 DISPLAY 16 7 4 FLAT BATTERIES 16 7 5 ICON LIST WOOD 17 7 6 POWER MANAGEMENT 17 8 NAVIGATION MENU 17 9 START UP INSTRUCTIONS 17 9 1 DATE AND HOUR SETTINGS 17 9 2 ROOM PR...

Page 4: ...indicated in this manual prompt execution of extraordinary maintenance if necessary malfunctioning activity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The...

Page 5: ...ng faulty due to negligence or careless use wrong maintenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance f...

Page 6: ...the presence of forced ventilation or in premises which can go into negative pressure compared to outside 2 WOOD RECOMMENDED FEATURES For its products the Manufacturer recommends using class A1 or A1...

Page 7: ...ostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary for installation of the hermetic appliances that take air directly from outside Check and comply with the ventilation...

Page 8: ...ailable directly on the chimney flue plate 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following features the smoke outlet section must be at least double the inner section...

Page 9: ...is the case with concrete bricks etc wood composite materials etc In both cases make sure the passage for the flue pipe through the slab and the roof is wide enough to allow suitable safety distance 5...

Page 10: ...he RESY standards and wooden pallets All packaging materials can be re used for similar use or if necessary disposed of as urban waste in compliance with legislation in force Remove the strap binding...

Page 11: ...ould be subjected in the event of the opening of the safety bypass hatch Reassemble all the parts following the instructions in reverse WARNING THE SECTION OF THE EXHAUST PIPE MUST WITHSTAND TEMPERATU...

Page 12: ...f the outer thermostat function refer to the specific chapter in the following pages of this manual It is compulsory for the system to be grounded and have a differential switch in compliance with leg...

Page 13: ...0 S MATERIA PRIMA RAW MATERIAL A A B B C C D D E E F F 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 TUTTI GLI SVILUPPI FORNITI IN FORMATO DXF SONO TEORICI IL PARTICOLARE REALIZZATO DEVE ESSERE CONFORME AL DISEGNO...

Page 14: ...rolonged not use of command risk of oxidation and liquid leakage Nobis srl declares that the type of Handheld radio device complies with Directive 2014 53 EU The full text of the EU declaration of con...

Page 15: ...ust be enabled to allow the control unit to detect the presence of the external thermostat from the USER SETTINGS menu see the paragraph ENABLE EXTERNAL THERMOSTAT Enabling the external thermostat wil...

Page 16: ...nds of inactivity the remote control display blacks out and switches to SLEEP mode maintaining the remote connection with the appliance Press to reactivate it This Icon indicates the appliance status...

Page 17: ...led optional and enabled The menu is useful when you want to adjust the operating power to restart the appliance in pellet mode while Unica is running with wood 8 NAVIGATION MENU See the corresponding...

Page 18: ...From the STAND BY screen press to activate power modification Values range from 1 to 3 They are represented by black boxes visible below room temperature Make changes by pressing Confirm the new setti...

Page 19: ...ch subsequent load of wood the HOLD mode will be activated automatically This will maximize efficiency while minimizing emissions to the environment 9 7 COLD START Un Thanks to its flexibility Unica a...

Page 20: ...he need to lower the lever bringing it back to its initial position thus closing the by pass Without electricity Unica requires the combustion air valve to be opened manually using the handle located...

Page 21: ...th the only difference that it does not have 7 power levels but 3 plus PS which automatically follows the power set via remote control For further information see the same paragraph in the pellet mode...

Page 22: ...rating anomaly press OK to display more details The stove has detected an alarm condition press OK to view more details Note by resolving the condition causing the alarm Unica will continue to operate...

Page 23: ...ediately stop Unica in case of operation in pellet mode as for all the other Nobis products belonging to the pellet range Black Out with opening of the bypass hatch Safety thermal switch open door Pel...

Page 24: ...SE SAFETY VACUUM SWITCH FRONT VENTILATION K J LAPTOP CONNECTION technical support only USB CONNECTION technical support only REMOTE CONTROL EMERGENCY CABLE APPLIANCE SWITCH ON REMOTE UNIT SELECTION KE...

Page 25: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 25 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Page 26: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 26 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Page 27: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 27 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Page 28: ...o 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0031N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Reviews: