background image

Use and maintenance manual model “UNICA 10 V/C” - WOOD

ENGLISH

high temperatures.

• It is forbidden to make changes to the product 

unless expressly communicated in writing by the 

manufacturer.

• 

In  the  event  of  fire  in  the  chimney  flue,  contact    

the Fire Brigade immediately

.

• The product can be used by children over 8 

years of age and people with reduced physical, 

sensor or mental capacity, or without experience 

or the necessary know-how, provided they are 

supervised, or have received instructions on the 

safe use of the appliance and have understood 

the dangers involved. Children must not play with 

the appliance.

• Cleaning and maintenance intended to be 

carried out by the user must not be carried out by 

children without supervision.

• Do not dry the laundry on the the product. 

Fire 

hazard.

• 

Fuel  and  flammable  materials  must  be  kept  at 

necessary distance from the product. 

Fire hazard.

• The product must be electrically connected to a 

system equipped with a sufficient ground system.

• In the event of a fault on the switch on system, 

do not force switch on using flammable materials 

and consult an authorised technician.

• For the no hermetic product, installation is 

forbidden in small rooms and bedrooms.

• Installation is forbitten in surroundings with explosive 

atmospheres.

1.6  LEGAL WARRANTY

The user, to benefit from the legal warranty, must 

strictly comply with the provisions indicated in this 

manual. In particular:

• always work within the use limitations of the product;

• always carry out routine maintenance;

• authorise people to use the machine with proven 

capacity, attitudes and who are adequately 

trained for the purpose;

• 

use  original  spare  parts  and  specifically  for  the 

appliance model.

It is also necessary to provide a:

• 

fiscal receipt with the purchase date;

• 

a certificate of compliance issued for installation    

by authorised staff.

Non-compliance with the provisions contained 

in this manual will imply immediate expiry of the 

warranty on the product and on any spare parts 

assembled later.

1.7  EXCLUSIONS FROM THE WARRANTY

SoThe  warranty  excludes  all  malfunctions  and/

or damage to the appliance resulting from the 

following causes:

• 

damage caused by transport and/or movement;

• all parts resulting as being faulty due to 

negligence or careless use, wrong maintenance, 

non-conforming installation with that specified by 

the manufacturer (refer to the installation and use 

manual supplied with the appliance);

• further damage caused by wrong intervention    

by the user in an attempt to solve the initial fault;

• aggravated damage caused by further use of the 

appliance by the user once the defect was noted;

• in the presence of a boiler, any corrosion, scale or 

breakages caused by stray current, condensate, 

abrasion or acidity in the water, scale removal 

treatments carried out improperly, no water, 

sludge or limescale deposits;

• 

inefficiency of the chimneys, chimney flues or parts 

of the system on which the appliance depends;

• damage caused by tampering with the appliance, 

atmospheric agents, natural disasters, vandalism, 

electrical  discharge,  fire,  faulty  electrical  and/or 

plumbing system.

The following are also excluded from the warranty:

• parts subject to normal wear such as gaskets, 

glass, coverings and grates in cast iron, painted, 

chrome-plated or gold-plated parts, handles and 

electrical cables, lights, switch on resistor, indicator 

lights, knobs, all parts that can be removed from 

the fireplace (e.g. refractory, brazier);

• colour variations of painted and ceramic parts, as 

well as the ceramic cracks since they are natural 

features of the material and use of the product;

• masonry works;

• parts of the system (if present) not supplied by the 

manufacturer;

• Any technical intervention on the product to 

eliminate the aforementioned defects or resulting 

damage should therefore be agreed with the 

Technical Support Centre, which reserves the right 

to access or refuse the relevant job and in any 

case they will not be carried out under warranty, 

but rather Technical Support will provide the 

possible conditions to specifically agree upon and 

according to rates in force for the works to carry 

out.

• The user will also be responsible for the expenses 

which will be necessary to resolve any wrong 

technical intervention, tampering or however 

damaging factors for the appliance not 

attributable to the original defects.

• Notwithstanding the restrictions imposed by 

legislation and regulations, every warranty to 

contain atmospheric and acoustic pollution is also 

excluded.

1.8  SPARE PARTS

Only use original spare parts.

Do not wait for the components to wear from use 

before replacing them.

This measure promotes prevention of accidents 

Summary of Contents for UNICA 10 V/C

Page 1: ...EN Installation use and maintenance manual WOOD UNICA 10 V C...

Page 2: ...uctions manual can be reproduced or transmitted with any electronic or mechanical device including photocopying recording or any other saving system for any purpose other than the exclusive personal u...

Page 3: ...7 1 RECEIVER 15 7 2 KEYS 16 7 3 DISPLAY 16 7 4 FLAT BATTERIES 16 7 5 ICON LIST WOOD 17 7 6 POWER MANAGEMENT 17 8 NAVIGATION MENU 17 9 START UP INSTRUCTIONS 17 9 1 DATE AND HOUR SETTINGS 17 9 2 ROOM PR...

Page 4: ...indicated in this manual prompt execution of extraordinary maintenance if necessary malfunctioning activity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The...

Page 5: ...ng faulty due to negligence or careless use wrong maintenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance f...

Page 6: ...the presence of forced ventilation or in premises which can go into negative pressure compared to outside 2 WOOD RECOMMENDED FEATURES For its products the Manufacturer recommends using class A1 or A1...

Page 7: ...ostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary for installation of the hermetic appliances that take air directly from outside Check and comply with the ventilation...

Page 8: ...ailable directly on the chimney flue plate 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following features the smoke outlet section must be at least double the inner section...

Page 9: ...is the case with concrete bricks etc wood composite materials etc In both cases make sure the passage for the flue pipe through the slab and the roof is wide enough to allow suitable safety distance 5...

Page 10: ...he RESY standards and wooden pallets All packaging materials can be re used for similar use or if necessary disposed of as urban waste in compliance with legislation in force Remove the strap binding...

Page 11: ...ould be subjected in the event of the opening of the safety bypass hatch Reassemble all the parts following the instructions in reverse WARNING THE SECTION OF THE EXHAUST PIPE MUST WITHSTAND TEMPERATU...

Page 12: ...f the outer thermostat function refer to the specific chapter in the following pages of this manual It is compulsory for the system to be grounded and have a differential switch in compliance with leg...

Page 13: ...0 S MATERIA PRIMA RAW MATERIAL A A B B C C D D E E F F 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 TUTTI GLI SVILUPPI FORNITI IN FORMATO DXF SONO TEORICI IL PARTICOLARE REALIZZATO DEVE ESSERE CONFORME AL DISEGNO...

Page 14: ...rolonged not use of command risk of oxidation and liquid leakage Nobis srl declares that the type of Handheld radio device complies with Directive 2014 53 EU The full text of the EU declaration of con...

Page 15: ...ust be enabled to allow the control unit to detect the presence of the external thermostat from the USER SETTINGS menu see the paragraph ENABLE EXTERNAL THERMOSTAT Enabling the external thermostat wil...

Page 16: ...nds of inactivity the remote control display blacks out and switches to SLEEP mode maintaining the remote connection with the appliance Press to reactivate it This Icon indicates the appliance status...

Page 17: ...led optional and enabled The menu is useful when you want to adjust the operating power to restart the appliance in pellet mode while Unica is running with wood 8 NAVIGATION MENU See the corresponding...

Page 18: ...From the STAND BY screen press to activate power modification Values range from 1 to 3 They are represented by black boxes visible below room temperature Make changes by pressing Confirm the new setti...

Page 19: ...ch subsequent load of wood the HOLD mode will be activated automatically This will maximize efficiency while minimizing emissions to the environment 9 7 COLD START Un Thanks to its flexibility Unica a...

Page 20: ...he need to lower the lever bringing it back to its initial position thus closing the by pass Without electricity Unica requires the combustion air valve to be opened manually using the handle located...

Page 21: ...th the only difference that it does not have 7 power levels but 3 plus PS which automatically follows the power set via remote control For further information see the same paragraph in the pellet mode...

Page 22: ...rating anomaly press OK to display more details The stove has detected an alarm condition press OK to view more details Note by resolving the condition causing the alarm Unica will continue to operate...

Page 23: ...ediately stop Unica in case of operation in pellet mode as for all the other Nobis products belonging to the pellet range Black Out with opening of the bypass hatch Safety thermal switch open door Pel...

Page 24: ...SE SAFETY VACUUM SWITCH FRONT VENTILATION K J LAPTOP CONNECTION technical support only USB CONNECTION technical support only REMOTE CONTROL EMERGENCY CABLE APPLIANCE SWITCH ON REMOTE UNIT SELECTION KE...

Page 25: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 25 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Page 26: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 26 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Page 27: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 27 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Page 28: ...o 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0031N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Reviews: