12
Lower
neutral
lift
e) Use a hammer to insert the 2
nd
dowel pin (5, Fig. 5) into the 2
nd
hole of the axle.
The draw-bar is now assembled to the pump.
For the ACX 10E connect the control cable. Fix the cable at the pump side in a way that the cable holder
can be turned. Fix the cable before the plug with the pre assembled cable strip.
b.
Hydraulic valve adjustment
On the tiller of your pallet truck, you will find the control lever, which can be regulated in three positions:
a)
Lever (ACX10M)
Lower
:
handle up, the lever moves back to the neutral
when released
Slow lift
:
handle in center position
Quick lift
:
handle down
If necessary, you can adjust the lever according to following steps (Fig. 8):
•
If the forks do not elevate while the control handle is in the
Slow Lift
position
or
Quick Lift
position, turn
the adjusting nut on the adjusting bolt counter-clockwise until the
Slow Lift
position and the
Quick Lift
position work properly.
•
If the forks do not lower down while the control handle is in the
Lower
position, turn the adjusting nut
clockwise until the
Lower
position works properly.
•
If the forks do not lift slowly when the control handle is in the
Slow Lift
position, turn the adjusting nut
clockwise until the
Slow Lift
position works properly.
•
If the forks do not lift quickly while the control handle is in the
Quick Lift
position, turn the adjusting nut counter- clockwise until the
Quick Lift
position
works properly.
b)
Lever(ACX10E)
Lower
:
handle up, the lever moves back to the neutral
Neutral :
handle in center position
Lift
:
handle down
If necessary, you can adjust the lever according to following steps (Fig. 9):
•
If the forks elevate while pumping in the
Neutral
position, turn the adjusting nut on the adjusting bolt
clockwise until pumping action does not raise the forks and the
Neutral
position works properly.
•
If the forks descend while pumping in the
Neutral
position, turn the adjusting nut counter-clockwise
until the forks do not lower.
•
If the forks do not descent when the control handle is in the
Lower
position, turn the adjusting nut
clockwise until raising the control handle lowers the forks. Then check the
Neutral
position according to
fig. 9 and be sure that the adjusting nut is in the proper position.
•
If the forks do not elevate while pumping in the
Lift
position, turn the adjusting nut counter- clockwise
until the forks elevate while pumping in the
Raise
position. Then check the
Lower
and
Raise
position.
Fig. 8: Lever ACX10M
Lower
Slow lift
Quick lift
Fig. 9: Lever
ACX10E