19
Only travelling in
one direction
The accelerator and the
connections are damaged.
Check the accelerator and the
connections.
The battery is discharged.
Check the battery status at the
discharge indicator
The electromagnetic brake is
engaged.
Check the electromagnetic
brake
The stacker only
travels very slowly
The relating tiller cables are
disconnected or damaged
Check the tiller cables and
connections.
The controller is damaged.
Replace the controller.
The stacker starts
up suddenly
The accelerator not moves back to
its neutral position.
Repair or replace the
accelerator.
If the truck has malfunctions and can’t be operated out of the working zone, jack the truck
up and go with a load handler under the truck and safe the truck securely. Then move the
truck out of the aisle.