22
back through the menu structure. To set a bookmark, press one of the bookmark keys for about three
seconds, until the Bookmark Set screen is displayed. To jump to a set bookmark location, quickly press
the appropriate bookmark key (1, 2, or 3). Note that the bookmarks are not permanently stored in the
programmer. They are cleared when the programmer is unplugged.
The bookmark keys can be used to make parameter adjustment easier. For example, in adjusting the
throttle deadband, you might set a bookmark at the Throttle % readout [Monitor > THROTTLE %] and
another at the Throttle Deadband parameter [Program > THROTTLE DB]; this way you can easily toggle
between the readout and the parameter.
Connect the 1311
handheld programmer to the truck and switch on the power,
Program
parameter shown as below:
Menu 2
Menu 3
Menu 4
Menu 5
Value
Min Max
Unit
Mode
Settings
Mast Momentary
Switch Enable
On
Off
On
PD control
Enable
Off
Off
On
Motor type
define
1
0
32767
High Speed
Mode
Max Speed
4200
0
5000
rpm
Drive Current
100
5
100
%
Accel Rate
1.8
0.1
30
Seconds
Decel Rate
1.5
0.1
30
Seconds
Speed limitation
set
Mast High Max
Speed
2100
0
5000
rpm
Turning Switch Max
Speed
2100
0
5000
rpm
Arm close Standon
Max Speed
4200
0
5000
rpm
Arm close Wakier
4200
0
5000
rpm