17
7.
BATTERY CHARGING AND REPLACEMENT
•
Only qualified personnel are allowed to service or charge the batteries. Must follow the
instructions of this manual and the explanations of the manufacturer.
•
The truck is equipped with lead acid battery.
•
Recycling of batteries undergoes national regulations. Please follow these regulations.
•
By handling batteries, open fire is not allowed, as it may cause gas explosion.
•
In the area of battery charging neither burning materials nor burning liquids are allowed.
Smoking is prohibited and the area must be ventilated.
•
Park the truck securely before starting charging or assembling/replacing batteries.
•
Before finishing the maintenance work, make sure that all cables are connected
correctly and there are no disturbing towards other parts of
the truck.
a.
Replacement
Park the truck securely and press emergency button (13) to turn the power of the stacker. Remove the
battery cover and then remove the connector (25). After that, remove the battery with specialized
equipment. Note: if the equipment is not safe, the battery will be tipped over.
The battery assembling is in the reverse order. Please connect the positive terminal first, or it will cause
damage to the truck.
b.
Battery Indicator (assembled on tiller)
Fig. 11: Battery replacement
Fig. 12: Battery discharge indicator
The lead acid battery type for the truck:
PS12CB-C:1pcs, 24V-2PZS-210Ah
[624x212x602mm (L
×W×H)]
PS15CB-C:1pcs, 24V-3PZS-270Ah/ 24V-3PZS-350Ah
[624x284x627mm (L
×W×H)]
IT IS ONLY ALLOWED TO USE LEAD ACID BATTERY.
THE WEIGHT OF BATTERY WILL AFFECT OPERATION
OF THE TRUCK.
PLEASE CONSIDER THE MAXIMUM OPERATING
TEMPERATURE OF THE BATTERIES.