11
release of driving buttons and of the safety (belly) button (section 6f).
Check the function of driving with tiller in its vertical position (section 6d).
Check the function of the emergency brake by activating the emergency button.
Check the lifting and lowering functions by operating the buttons (section 6b and 6c).
Check the function of steering by turning the tiller from one end position to the other one. The
steering should be smooth, without jerks or abnormal sound.
Check if all bolts and nuts are tightened firmly.
Visual check if there are any broken electric wires.
If supplied with a backrest extension, check it for damages and correct assembling.
Check the presence of warning stickers and signs (section 2c and section 12)
6. OPERATING INSTRUCTIONS
BEFORE OPERATING THIS TRUCK, PLEASE FOLLOW THE WARNINGS AND SAFETY
INSTRUCTIONS (CHAPTER 3).
Make sure, that the load is palletized and stable and that the daily inspection is carried out.
Steps to activate the truck: start the emergency button and press the button
on display.
Press the horn button (Fig.7,15) to activate the audible warning signal.
Steps to shutdown the truck: shutdown the emergency button.
a. Parking
DO NOT PARK THE TRUCK ON INCLINED SURFACES
The truck is equipped with an electromagnetic failsafe stopping and parking brake.
Always lower the forks fully. Press the emergency button (5).
b. Lifting
DO NOT OVERLOAD THE TRUCK!
THE MAXIMUM CAPACITY OF
PTE15-C/SPTE15-C
IS 1500 kg.
Fig.7: Tiller operating controls