TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
Machine not operating.
Power cord not plugged in.
Connect to power supply.
Machine not operating.
Damaged power cord.
Contact Service Center.
Tripped circuit breaker in building.
Reset breaker in building.
Loose or damaged internal wiring.
Contact Service Center.
Brush not turning.
Machine circuit bnreaker tripped.
Reset breaker. Check for brush obstruc-
tion or low brush setting.
Broken belt.
Replace belt.
Belt not adjusted properly.
Readjust belt.
Defective brush switch.
Contact Service Center.
Defective brush motor.
Contact Service Center.
Poor pick–up.
Filter bag full.
Empty bag.
Poor pick–up.
Secondary vacuum filters dirty.
Clean and replace.
Air flow lever in wrong position.
Move lever to proper setting.
Brush intake area obstructed.
Check for obstruction and remove.
Pick–up hose or housing plugged.
Check for obstruction and remove.
Gasket leak.
Replace gasket.
Brush not adjusted properly.
Reset brush adjustment.
Worn brush.
Adjust or replace.
Vacuum motor not
operating.
Thermal overloads activated due to plug or
obstruction.
Inspect and clean.
operating.
Vacuum switch defective.
Contact Service Center.