14
Speed Scrub 350 9016424 (09-2017)
OPERATION
INSTALLING BATTERIES
WARNING: Batteries emit hydrogen
gas. Explosion or
fi
re can result. Keep
sparks and open
fl
ame away when
charging.
FOR SAFETY: When servicing machine, wear
appropriate personal protection equipment as
needed. Avoid contact with battery acid.
BATTERY SPECIFICATIONS
Requires four 6 volt deep-cycle batteries,
≤
240 Ah @ 20 hr.
Contact distributor or Tennant for battery
recommendations.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and remove key.
1. Lift the recovery tank to access the battery
compartment.
2. Carefully install the batteries into the battery
compartment tray and arrange the battery
posts as shown.
FOR SAFETY: When servicing machine, use
a hoist or adequate assistance when lifting
batteries.
3. Using the supplied battery post boots, connect
the cables to battery posts, RED TO POSITIVE
(+) & BLACK TO NEGATIVE (-). Tighten
cable connections to batteries per battery
manufacturer speci
fi
cations.
RED
BLACK
IMPORTANT: Before charging batteries, make
sure the battery charger and the machine’s
battery discharge indicator are properly set for
battery type. Failure to properly set will result
in battery damage. See BATTERY CHARGER
SETTINGS.
ATTENTION: Do not disconnect battery cables
while charger is plugged in, circuit board
damage may result.
ATTENTION: Batteries serve as a counter-
weight. Always maintain the minimum
counterweight to ensure machine stability and
traction.
IRIS Battery Charging Metrics Notifi cation:
Machines equipped with capability to report
battery charging data via IRIS are supplied with
a charger and set of batteries from the factory.
When a battery reaches its end of life and must
be replaced, Tennant highly recommends that
the same battery type be used to continue to
maximize the machines performance. In the event
a battery with a different amp hour (AH), type
(Flooded, AGM, Gel), or manufacturer is selected
for replacement please contact Tennant technical
service department for assistance in determining
the feasibility of the replacement batteries and
if so, selecting the correct charging profi le.
Availability of IRIS battery metric reporting is not
guaranteed with third party supplied batteries.
NOTE: If there is liquid in battery compartment,
drain battery compartment before installing
batteries. See BATTERY COMPARTMENT DRAIN
VALVE.