45
Speed Scrub 350 9016424 (09-2017)
MAINTENANCE
4. Using a small standard screwdriver, turn the
dial to the appropriate battery type according
to the following chart.
Dial
Position
Battery Description Settings with
AH Ranges
0
CAN-BUS setting*
1
Wet, Trojan 180-260 AH
2
Wet, Trojan 270-360 AH
3
Wet, Enersys/Tab 200-350 AH
4
AGM, Tianneng 180-260 AH
5
AGM, Discover 200-350 AH
6
Gel, Sonnenschein 80-150 AH
* The CAN-BUS setting, dial position “0”, is the
software setting that is programmed to match
battery type supplied with machine. When the dial
is manually changed to a different setting, it should
not be reset back to “0” otherwise battery damage
may result. Service Application Software is
required to reset dial back to “0”. Contact Service.
5. Re-apply the display label.
6. To set the BDI for the new battery type, plug
the on-board battery charger cord into an
electrical outlet. The machine’s software will
automatically reprogram the BDI to the new
battery type.