Actuator Voltage Data
Actuator Travel Direction Wire #
Color
Polarity
Notes
17
Purple
−
18
Gray
"
+
"
17
Purple
"
+
"
18
Gray
−
19
White
−
20
Tan
"
+
"
19
White
"
+
"
20
Tan
−
DOWN
UP
Squeegee
Voltage at actuator connector will be
approx. 24 VDC for 2 seconds, then
approx. 12 VDC for 2 seconds for both
UP & DOWN travel
Scrub
Head
DOWN
UP
Voltage at actuator connector will be
approx. 24 VDC for 4 seconds
Voltage at actuator connector will be
approx. 24 VDC for 4 seconds, then
approx. 11 to 12 VDC for 2 to 4 seconds
Pressing the “One Step Scrub Button” will lower the squeegee and scrub head
Only one actuator will be energized at any given time – squeegee is lowered
first, then the scrub head
Squeegee actuator uses internal limit switches to stop travel in upward and
downward travel
Scrub head actuator travel is controlled by monitoring actuator current in
upward travel and brush motor current in downward travel
Squeegee actuator can also be operated by pressing the “Vacuum Fan/
Squeegee Button”, without operating scrub brushes
i
18
Summary of Contents for SpeedScrub Rider
Page 1: ... 331145 Rev 00 331145 SpeedScrub Rider Service Information and Hygenict Tanks Featuring ...
Page 4: ...ii ...
Page 7: ...1 2 3 4 5 1021038 Speed Scrub Ladder Schematic page 1 of 2 3 ...
Page 8: ...1 2 3 4 5 1021038 Speed Scrub Ladder Schematic page 2 of 2 4 ...
Page 9: ...1 Speed Scrub Wire Harness Group page 1 of 4 5 ...
Page 10: ...1 Speed Scrub Wire Harness Group page 2 of 4 6 ...
Page 11: ...1 Speed Scrub Wire Harness Group page 3 of 4 7 ...
Page 12: ...2 Speed Scrub Wire Harness Group page 4 of 4 8 ...