Speed Scrub – Operational Modes & Interlocks
Mode
Entry Sequence
Indicator
Function
−
Directional Switch Forward
−
Propel Pedal Depressed
−
Directional Switch Reverse
−
Directional Switch in Reverse position
−
Propel Pedal Depressed
−
Horn Sounding continuously ON & OFF (except in
"Hospital" mode)
Scrub Mode
−
Press One Step Scrub Button
(ON)
−
One Step Scrub LED ON
Activate Scrub Brush, Squeegee,
Vacuum Fan & Solution Flow
operations
−
Press One Step Scrub Button
(ON)
−
One Step Scrub & FaST LED's ON
−
Press FaST Button (ON)
−
Solution Flow LED's OFF
−
Press One Step Scrub Button
(ON)
−
One Step Scrub & Solution Flow LED(s) ON
−
Press FaST Button (OFF)
−
FaST LED OFF
−
Press One Step Scrub Button
(ON)
−
One Step Scrub LED ON
−
Press Vacuum Fan/Squeegee
Button (OFF)
−
Vacuum Fan/Squeege LED OFF
−
One Step Scrub LED OFF
−
Vacuum Fan/Squeegee LED ON
−
Lower Brush Pressure (#1) LED ON; Middle (#2) &
Upper (#3) LED's OFF
−
Lower Solution Flow (#1) LED ON; Middle (#2) &
Upper (#3) LED's OFF
−
Press Brush Pressure
Decrease (-) to one LED
−
Lower Brush Pressure (#1) LED ON; Middle (#2) &
Upper (#3) LED's OFF
−
Press FaST Button (ON)
−
FaST LED ON (Solution Flow LED's OFF)
Recovery Tank
Full
−
Recovery Tank Full (Float
Switch Closed)
−
Recovery Tank Full LED ON
Disable Scrub function (Operator can
get an additional minute of operation by
re-engaging scrub system with One
Step button)
Battery
Discharged
−
Battery voltage at or below full
discharge voltage
−
Red LED (on Battery Gauge) blinking
Disable Scrub function (Operator can
get an additional minute of operation by
re-engaging scrub system with One
Step button)
−
Fault LED ON and any one or more of the
following:
Lower Brush Pressure (#1) LED ON (Right Motor)
Upper Brush Pressure (#3) LED ON (Left Motor)
Upper Solution Flow (#3) LED ON (Vacuum Fan)
Prevent damage to Scrub Brush
Motors or Vacuum Fan Motor –
Scrub function shuts off
Double Scrub
(no water
pickup)
Water pickup
(no Scrub)
Accessory
Motor High
Current Fault
−
Controller sensed an Over
Current condition in the
Scrub Brush Motors or
Vacuum Fan Motor
Forward
Reverse
FaST Mode
Conventional
Solution Mode
−
Press Brush Pressure
Decrease (-) to one LED
−
Press Solution Flow Decrease
(-) to one LED
−
Solution Tank Empty LED ON
Disable Scrub function (Operator can
get an additional minute of operation by
re-engaging scrub system with One
Step button)
Low Power
Mode
Low Power
Mode w/ FaST
Solution Tank
Empty
Reduce Scrub Brush and Fan speeds
(to prolong battery life, reduce noise,
lower water usage)
Reduce Scrub Brush and Fan speeds
(to prolong battery life, reduce noise,
lower water usage)
−
Solution Tank Empty (Float
Switch Open)
Activate Conventional solution flow
when scrub and propel are engaged
Apply cleaning solution with no water
pickup
−
Press Vacuum Fan/Squeegee
Button (ON)
Collect solution on floor with squeegee,
without scrubbing floor
−
Directional Switch in Forward position
Forward movement of machine
Reverse movement of machine
Activate FaST foam solution flow when
scrub and propel are engaged
24
Summary of Contents for SpeedScrub Rider
Page 1: ... 331145 Rev 00 331145 SpeedScrub Rider Service Information and Hygenict Tanks Featuring ...
Page 4: ...ii ...
Page 7: ...1 2 3 4 5 1021038 Speed Scrub Ladder Schematic page 1 of 2 3 ...
Page 8: ...1 2 3 4 5 1021038 Speed Scrub Ladder Schematic page 2 of 2 4 ...
Page 9: ...1 Speed Scrub Wire Harness Group page 1 of 4 5 ...
Page 10: ...1 Speed Scrub Wire Harness Group page 2 of 4 6 ...
Page 11: ...1 Speed Scrub Wire Harness Group page 3 of 4 7 ...
Page 12: ...2 Speed Scrub Wire Harness Group page 4 of 4 8 ...