OPERATION
Nobles Strive Compact (03--08)
12
RECOMMENDED STOCK ITEMS
Refer to the Parts List Manual for recommended stock
items. Stock Items are clearly identified with a bullet
preceding the parts description. See example below:
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
Machine does not operate.
Faulty power cord.
Replace power cord.
Tripped circuit breaker.
Unplug power cord and determine
cause. Reset 15 amp circuit breaker
button. Contact Service Center if cir-
cuit breaker continues to trip.
Rollers do not spin
Tripped circuit breaker.
Readjust roller pressure knob. Reset 5
amp circuit breaker button.
Unplug power cord and inspect rollers
for obstruction. Reset 5 amp circuit
breaker button.
Broken brush belt.
Contact Service Center.
Faulty roller motor or worn carbon
brushes.
Contact Service Center.
Poor water pickup.
Loose accessory tool vacuum hose
port cover.
Check vacuum hose port cover.
Worn rollers
Replace rollers.
Clogged shut--off float.
Clean debris from shut--off float.
Clogged vacuum intake screen.
Clean debris from intake screen.
Clogged vacuum shoes.
Clean debris from vacuum shoes.
Clogged vacuum shoe hose.
Contact Service Center.
Worn tank cover gaskets.
Replace gaskets.
Faulty vacuum motor.
Contact Service Center.
Uneven or no spray.
Empty solution tank.
Refill solution tank.
Clogged spray tip.
Clean or replace tip.
Improper spray tip angle.
Adjust spray tip angle.
Faulty spray tip.
Replace spray tip.
Clogged solution hose screen.
Clean debris from solution tank
screen.
Damaged solution hose.
Contact Service Center.
Faulty solution pump.
Contact Service Center.
Excessive foam/cream appears
on the floor
Cleaning detergent was added to solu-
tion tank.
Drain and rinse out solution tank and
refill with water only, do not add clean-
ing detergent.