Lamp fails to ignite
Lamp failure.
Replace lamp if any abnor-
(continued)
malities or damage to the
envelope or contacts are
present.
Socket failure.
Remove any contamination or
replace if damage is found.
Safety interlock is not
Interlock rod must contact the
engaged.
window when the front cover
is secured and moves freely
when not engaged.
Power Switch/ Circuit
Power source over-
Check power source for
Breaker Trips
current condition.
correct Voltage and Current
ratings.
Wires are shorting on
Repair as necessary to pre-
or within the fixture.
vent future shorting.
Power Switch/ Circuit Breaker
Replace if damage is found.
is not correctly operating.
Fixture Display
Power cord is not plugged in
Plug into source that has
is Inoperative
or the source is not energized.
suitable electricity available.
Power Switch/ Circuit Breaker
Push to the ON position.
is not in the ON position.
FUNCTION SELECTION
Display should reactivate
BUTTON is not operating.
when the button is pressed.
Membrane switch ribbon
Connect termination header
cable is not fully connected
into DMX board.
to DMX board.
Internal power terminals
Connect termination plugs
are not connected.
if unplugged.
Internal fuse blown.
Replace fuse.
17