Humidity and Temperature
During operation, ambient relative humidity should never exceed ninety
percent and ambient air temperature must remain between 32
°
F and 113
°
F
(0
°
C and 45
°
C).
Safety Precautions
Follow these safety instructions whenever you are working with the gateway.
Caution
Read and follow all of these precautions before you work near any
power source.
!
Circuit breakers must be installed in the fixed wiring on all circuits to
which the gateways are connected. Ensure that all of the circuit breakers
are easily accessible.
!
For installations in North America, use a 120 VAC, 20A fuse circuit
breaker for the circuit branch.
!
For installations outside North America that use 230 VAC, use a
230 VAC, 2A fuse circuit breaker.
!
Use the gateway device within the electrical ratings indicated on the back
of the device and in the product documentation.
Follow the requirements of all building and electrical codes before, during,
and after installation of the gateway.
Warning
The gateway requires protection against short-circuits (overcurrent).
Always use overcurrent protection on all conductors of electrical current
to which the gateway is connected.
Summary of Contents for 100i
Page 1: ...Nokia100i Installation Guide Part No N451654001 Rev A Published June 2005 ...
Page 4: ...4 Nokia 100i Installation Guide ...
Page 8: ...8 Nokia 100i Installation Guide ...
Page 22: ...1 Overview 22 Nokia 100i Installation Guide ...
Page 26: ...2 Installing the Gateway 26 Nokia 100i Installation Guide ...
Page 58: ...4 Installing and Replacing Optional Cards 58 Nokia 100i Installation Guide ...
Page 62: ...5 Troubleshooting 62 Nokia 100i Installation Guide ...
Page 70: ...B Compliance Information 70 Nokia 100i Installation Guide ...