Nokia N97 mini
RM-553 / RM-555
Service Manual Level 1&2
25
Confidential
Copyright © 2009 NOKIA
All rights reserved
Version 1.0
ISSUE 1
12.3
Troubleshooting
When touching the points on the phone UI, there is a 30 second timeout. If this expires without
receiving 3 points, the procedure will abort.
Simply press “Retry” to start again.
If the phone connection to Phoenix is disrupted (e.g. cable is disconnected), the recalibration
will stop.
Make sure the connections are correct, and restart the calibration procedure.
For verification failure issues:
Send/End keys not working
Touch panel is not working
Drawn lines are not following the tip of the SS-93/stylus
There are large “dead” areas where lines cannot be drawn
Restart Phoenix and retry the calibration again.
If verification continues to fail, contact your next level of support.