RM-12
Nokia Customer Care
Issue 1 11/2004
COMPANY CONFIDENTIAL
49
Copyright © 2004 Nokia. All Rights Reserved.
Charging
Connect charger
and read Vchar
voltage by
Phoenix ACP-12
5.7V
Perform EM
calibration by
Phoenix and
JBV-1
Not
charging
NO
Measure Vchar
from fuse F2020
5.7V
Change fuse
F2020
NO
Measure Vchar
from L2020 5.7V
Change L2020
NO
Connect
service battery
and read BSI
by Phoenix
75kohm
YES
YES
NO
Perform EM
calibration by
Phoenix and
JBV-1
Read BSI by
Phoenix. With
servce battery
75kohm
Disassemble
phone and check
Battery contacts .
Phone in jig.
Measure
voltage on
R2202, Normal
mode 1.3V
Change R2201
and R2202
NO
YES
Connect charger
and read Vchar
voltage by
Phoenix ACP-12
5.7V
Measure Vchar
from fuse F2020
5.7V
YES
Change fuse
F2020 and V2020.
NO
Charging OK
NO
Read BSI by
Phoenix. With
servce battery
75kohm
Flash phone SW
NO
NO
YES
Flash phone SW
NO
Charging OK
Charging OK
YES
Disassemble
phone. Check
charger connector.
NO
NO
YES
Flash phone SW
Charging OK
Disassemble
phone and change
R2200
NO
Charging OK
Change UEM
D2200
NO
Charging OK
NO
YES
YES
Perform EM
calibration by
Phoenix and
JBV-1
100kohm
100kohm
100kohm
Note! OMAP, UEM and UPP are unchangeable.