Appendix A: RF Troubleshooting
A-16
Company Confidential
Copyright
©
2005 Nokia. All rights reserved
•
Measurement can be done with an oscilloscope and a probe.
•
Connect the probe to R7531.
•
WTXDET signal should be constant DC-voltage. Voltage level should change if TX power is changed.
Vcontrol is lower on lower power levels and higher if higher power levels are used.
•
WTXDET should be about 325 mV with power level +10 dBm, about 1.03 V with power level
+21 dBm and about 150 mV when power levels below 0 dBm are used.
•
NOTICE: Perform WCDMA transmitter tests with > 0 dBm power only in RF shielded environment.
•
If WTXDET –signal is not as expected follow the same troubleshooting instructions as in:
SMPS get correct control voltage from the WCDMA power detector (signal Vcontrol)?