Appendix A: RF Troubleshooting
Nokia Customer Care
Company Confidential
Copyright
©
2005 Nokia. All rights reserved
A-
105
change if RX channel is changed. VC is lower on lower channels and higher if higher channel
numbers are used.
4.2.4.8.1.1 VCP1-voltage ok?
•
WCDMA receiver has to be active before VCP1 voltage can be measured. Procedure is explained in
section “Receiver troubleshooting”.
•
Measurement can be done with an oscilloscope and a probe.
•
Connect the probe to C7507.
•
VCP1 voltage should be about 4.75 V.
4.2.4.8.1.1.1 C7507 and C2222 working properly?
•
Check that the components are in place and solder joints are ok
•
Disconnect the power supply from the phone and use an ohmmeter to check that C507 and C2222
are not short-circuited.
4.2.4.8.1.1.2 Retu ok?
4.2.4.8.1.1.3 Hinku (N7500) ok?
4.2.4.8.1.2 Balun T7501 ok?
•
WCDMA receiver has to be active before RX VCO’s output frequency and output level can be
measured. Procedure is explained in section “Receiver troubleshooting”.
•
Measurements can be done with a spectrum analyser and an RF probe. Spectrum analyser centre
frequency should be set according the used RX channel (see section “Frequency mappings”). RBW
and VBW = 1 MHz, Span
≤
200 kHz.
•
Check the level of the VCO frequency in T7501 outputs. The level should be about -25…-35 dBm. If
the signal level is correct in the input (about -20…-30 dBm) but output level is not as expected
then replace T7501.
4.2.4.8.1.3 Are components near the RX VCO ok?
R7501, C7516, R7505, C7524 and C7522 working correctly?
•
Check that components are in place and solder joints are ok
•
Disconnect the power supply from the phone and check resistors resistance values with an
ohmmeter.
•
Use an ohmmeter to check also that capacitors are not short-circuited
4.2.4.8.1.4 Replace Hinku (N7500) or RX VCO (G7500) or both
4.2.4.8.2 Replace RX VCO G7500
4.2.4.9 Is RX VCO signal level in the T7501 output high enough?