4 Channel receiver with self-learning, it manages standard
codes from 12 till 80 and rolling HCS© or rolling EB
P1
P2
L2
L1
L3
ON
+
ANTENNA
-
ANTENNA
- NEGA
TIVE 12/24
+ POWER SUPPL
Y
N.O.
COM.
N.O.
COM.
N.C.
OUT 1
1 2 3 4 5
7
6
8
RX2-XL
Removable
memory
OUT 2
1 2 3 4 5 6 7 8 9
► CONNECTION OF THE RECEIVER
POWER SUPPLY (3 and 4).
The receiver can be powered
from 12 to 24 volt in AC and DC as well. The polarity must
be used in case of DC (positive on clip nr. 4).
ANTENNA (1 and 2).
The antenna must be connected
with positive (the spirit) on the contact no.1 and negative
(stocking). If only one is used (17cm for freq. 433,92 Mhz
- 8.5 cm for freq. 868 Mhz), this has to be connected to
contact n°1.
OUTPUT (from 5 to 9).
The normally opened rele´of
exit 1 is on contact n° 7 and 8 while the normally closed
contact is on contact n° 8 and 9. For output 2 the normally
opened contact is present only on clips n° 5 and 6. It is
recommended not to connect such contacts to high tension
and to make sure that the current not exceed 1 ampere.
► USE OF RECEIVER
RESET PROCEDURE
This operation cancels all codes in the memory. It is
necessary to execute the memory´s reset before learning
the fi rst TX, so that the previously codes and the code that
are not used, are not in the memory:
1. Make sure that the output are deactivated
(The green led L1 and L2 are turned off).
2. Make sure that the receiver is not learning. The red
led L3 must be switched off.
3. Keep pressed the button P1 till the red led it is
switched on. (10 seconds) and then release it.
4. Wait that the red led will be switched off or fl ashing.
MEMORY CODES´S CAPACITY
The receiver is in a position to manage till 190 transmitters
rolling (till 4 channels for transmitter) and till 190
transmitters with standard code (1 channels for TX).
TYPE OF CODES´S MANAGE.
This receiver is in a position to manage the standard codes
from 12 to 80 bit and rolling codes type HCS© or Rolling
EB.
DESCRIPTION OF THE EBR CODE
The EBR code is a rolling code and it cannot be copied.
Each EBR remote control has its own production code
which cannot be changed. Moreover the EBR code
is composed of an installation number which can be
programmed from the installer. This installation number
is important for the EBR receiver to know if it can be
automatically memorized or not. If a EBR remote control
has been already memorized with the same installation
number, it is not necessary to learn it in the receiver.
WARNING!!! IT IS NECESSARY TO EXECUTE
THE MEMORY´S RESET!!!
DIP 1
ON
EB Rolling
code function activated
DIP 2
ON
HCS rolling
code function activated
DIP 3
ON
Reduce the output activation from 0.8 to 0.3 s
DIP 4
ON
The receiver will accept only the same type of code of the
fi rst memorized remote controls, the next one should have
the same type of code.
DIP 5
ON
If you are using the HCS rolling code function, DIP 2 in ON,
keep pressed button 1 and 2 of the remote control which
has been already memorized, the codes learning is in the
OUT1. If you are memorizing EB rolling code, DIP1 ON, you
activate the self-memorization of the remote controls with the
same installation code.
DIP 6
ON
Excluding the step-by-step function on the time outputs.
DIP 7
ON
It activate the managing of the inverted code
(differential Manchester encoding)
DIP 8
ON
Not used
► PROGRAMM
DIP:
Read carefully the operating manual
Read carefully this manul before installation
and keep it for the future.