background image

6

NookBox

Installation Guide

Remote Keypad KP-35

Beep Control:  

 

 

Entry/Exit Beep: 

Set to “Turn On” or “Turn Off” this function to program whether the Keypad should emit warning beeps during Entry  

 

 

Delay or Exit Delay timer.

 - 

Alarm Beep: 

Set to “Turn On” or “Turn Off” this function to program whether the Keypad should emit warning beeps when an alarm is  

   activated

Panic Alarm:  

 

Select to enable or disabled the dual key panic alarm function.

 

Fire Alarm:  

 

Select to enable or disabled the dual key fire alarm function.

 

Medical Alarm:  

 

 

Select to enable or disabled the dual key medical alarm function.

 

Quick Arm:  

 

Select to enable the quick arm function. When enabled, the user can directly enter Away Arm or Home Arm mode without entering user   

 

PIN code.

Press       key to exit User Menu.

Mode Change Function

 • 

After entering the PIN code, press Arm key to enter “Away Armed” mode. “Away Armed” will be displayed on the LCD screen  

 

 

    along with long beeping sound indicating successful operation.

 • 

After entering the PIN code, press Home Arm key to enter “Home Armed” mode. “Home Armed” will be displayed on the LCD  

 

 

    screen along with 3 beeps indicating successful operation.

 

•  After entering the PIN code, press OK key to enter “System Disarmed” mode. “System Disarmed” will be displayed on the LCD     

 

 

    screen along with 2 beeps indicating successful operation.

 • 

“Counting Down” will be displayed on the LCD screen along with 1 beep every second when the system begins to countdown Exit/  

 

            Entry Delay.
 • 

“Operation Error” will be displayed on the LCD screen along with 2 beeps indicating unsuccessful operation.

 • 

“Fault Display” will be displayed on the LCD screen along with 3 beeps indicating arming fault.

 • 

“Incorrect PIN Code” will be displayed on the LCD screen along with 4 beeps indicating incorrect password submission. 

NOTE:

 • 

 After 30 seconds without receiving any signal from the Control Panel, the power goes off and it returns to Stand-by mode.

 

•  If submitting incorrect PIN Code for 5 times within 10 minutes, the Remote Keypad will be automatically locked up for 5 minutes. During  

 

    this period, any operation will be invalid. When the lockup time expires, the Remote Keypad will sound 1 long beep.

Dual Key Alarm Function

 • 

The dual key alarm function allows user to activate alarm by pressing and holding two keys on the Keypad for 3 seconds. The functions  

 

   maybe enabled or disabled using Keypad menu and are disabled by default. The user must first activate them in User Menu to use these       

 

   features.

 • 

Panic Alarm: Press Button 1 + 3 to trigger a Panic Alarm.

 • 

Fire Alarm: Press Button 4 + 6 to trigger a Fire Alarm.

 • 

Medical Alarm: Press Button 7 + 9 to trigger a Medical Alarm.

Fault Conditions

 • 

If the Control Panel is under “Armed Mode”, you CANNOT activate Home mode by using Remote keypad. If you do so, the Remote Key  

 

   pad will sound 2 beeps indicating the Control Panel is under Arm Mode.

 • 

Press 4-digit PIN Code followed by Arm key or Home Arm to change mode. If there is a fault, then Remote keypad will beep 3 times. The     

 

   Yellow LED will light up when any fault situation is detected.

 • 

If submitting incorrect PIN Code for 5 times within 10 minutes, the Remote Keypad will be automatically locked up for 5 minutes. During    

 

   this period, any operation will be invalid. When the lockup time expires, the Remote Keypad will sound 1 long beep.

Summary of Contents for KP-35

Page 1: ...1 NookBox Installation Guide Remote Keypad KP 35 Remote Keypad KP 35 Installation Guide...

Page 2: ...outs It also has a tamper protection switch which will be activated upon any attempt of unauthorized opening of the cover The Keypad utilizes ZigBee technology for wireless signal transmission ZigBee...

Page 3: ...umeric Keys 5 Key 6 Key 7 Backlit OK Key To confirm the keyed in data or confirm the selection 8 Backlit Key Use this key for deleting a digit canceling the selection aborting the current screen and r...

Page 4: ...e Device Guideline ZigBee is a wireless communication protocol that is reliable has low power consumption and has high transmission efficiency Based on the IEEE802 15 4 standard ZigBee allows a large...

Page 5: ...in the system control panel and press OK to confirm User Menu The Keypad will communicate with the system to retrieve information before entering User Menu The system is always automatically disarmed...

Page 6: ...nsuccessful operation Fault Display will be displayed on the LCD screen along with 3 beeps indicating arming fault Incorrect PIN Code will be displayed on the LCD screen along with 4 beeps indicating...

Page 7: ...t Keypad to default value Reset Default will be displayed on the LCD screen along with 3 beeps indicating successful operation All learnt in data will be cleared Entry Exit Beeps will be disabled Alar...

Page 8: ...8 NookBox Installation Guide Remote Keypad KP 35...

Page 9: ...9 NookBox Installation Guide Remote Keypad KP 35 For more information visit www getnookbox com...

Reviews: