12
7
Module Installation
7.1
Control Module
An optional module mounting bracket kit is available for purchase from NORAC.
Item
Part Number
Name
Quantity
B20
43708
UC5 MOUNTING BRACKET KIT (CONTROL AND INPUT MODULES)
1
1.
Refer to
Figure 1
and
Figure 10
.
2.
Securely mount the control module (E01) near the bypass valve on the front right side of
the sprayer, near the sprayer CANbus connection, using screws, cable ties or optional
brackets.
3.
Connect cable C20 to the control module. Cable C20 must be connected to the end of the
control module with only one Deutsch connector. The free hanging ends of C20 are
connected to the sprayer CANbus as labeled on the wires.
4.
Connect the power cable to +12V and ground and then connect the other end to one of
the two CANbus connectors on the end of the control module.
5.
Route cable C01 from the other CANbus connector to the rear of the sprayer and connect
to a 3-way coupler (E10).
6.
Connect both C05 cables to the 3-way coupler and then connect the other ends to the
wing sensors using a 2-way coupler with termination (E20).
Figure 10: Control Module Mounting