18
4.6
H
YDRAULIC
I
NSTALLATION
WARNING!
The hydraulic system creates very
high pressure. Before disconnecting
any hydraulic lines ensure all pressure
has been bled from the system.
When changing the boom hydraulic
hoses leave the booms in
TRANSPORT POSITION.
IMPORTANT:
Component failure due to oil
contamination is not covered under
the UC4+ Spray Height Control
system warranty. It is recommended
that a qualified technician does the
hydraulic installation.
4.6.1
Valve Assembly
1.
On a clean surface remove all plastic
plugs from the NORAC hydraulic Valve
(
V01
) (
Figure 22
).
Figure 22: NORAC Valve Block
2.
Install the orifices (
F08
) into the "B"
ports
with the notch facing outward
as shown in
Figure 23
.
3.
Install the 6MB-6MJ fittings (
F05
) into
the “B” ports and tighten to 18 ft-lbs.
4.
Install the 6MBP plugs (
F09
) into the
“A” ports and tighten to 18 ft-lbs.
Figure 23: Valve Block Assembly
Summary of Contents for UC4+ Apache 1010 2005+
Page 9: ...6 Figure 3 Hydraulic Plumbing Schematic ...
Page 27: ...24 5 ELECTRICAL REFERENCE CABLE DRAWINGS 5 1 ITEM C02 44668 CABLE SENSOR BRANCH ...
Page 28: ...25 5 2 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL ...
Page 29: ...26 5 3 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Page 30: ...27 5 4 ITEM C05 44674 CABLE UC4 SENSOR ROLL BIAS ...
Page 31: ...28 5 5 ITEM C10 44650 39 CABLE POWER GENERIC SELF PROPELLED L 100 2 54m ...
Page 32: ...29 5 6 ITEM C11 44651 03 CABLE VALVE EXTENSION GENERIC 365 9 27m ...
Page 33: ...30 5 7 ITEM C12 44658 18 CABLE UC4 VALVE AP2 MAIN ...
Page 34: ...31 5 8 ITEM C13 44658 17 CABLE UC4 SENSE AP2 ...
Page 35: ...32 5 9 ITEM C14 44658 99 CABLE UC4 INTERFACE POWER PIGTAIL FUSED ...