12
where a setting cannot be changed, the +/- toggle switch is ignored.
4.6.4
AUTO/MANUAL switch (YES)
The UC4 boom control system has two operational modes – automatic and
manual. This switch changes the operational mode of the system. In
automatic mode (AUTO), the control panel will regulate the height of each
boom to a predetermined set point. In manual mode (MANUAL), the
sprayer functions as if no automatic control system is present.
When the system is in AUTO the operator can override automatic control
by operating the manual switches on the sprayer's boom controls (usually a
joystick or multifunction handgrip).
The AUTO switch also provides the alternate function "YES". In some
instances the control panel may prompt the operator with a question that
requires a yes or no response.
4.6.5
POWER switch
This switch is located on the left side of the panel and is used to turn the
power to the system on or off. For safety reasons, the system always
powers up in manual mode. Consequently it is important to make sure that
the power switch cannot be accidentally bumped during field operation.
4.7 Remote Controls
Remote control of several functions on the UC4 panel is possible. Remote
AUTO and remote MANUAL switches can be wired to the control panel.
This feature allows the operator to control the mode of the UC4 system
from an external switch or controller.
A motion inhibit wire is also available that will stop automatic control
actions unless the sprayer indicates that it is in motion. See Section 6.6.4.1
for more information on remote control settings.