33
* Control System Test *
Step 8
↓↓↓↓
55 MM 47
55 MM 47
55 MM 47
55 MM 47
•
Normal Operating Display is shown, an example is shown above.
•
CAUTION – IN THE FOLLOWING PROCEDURE, SWITCH TO
MANUAL IMMEDIATELY IF THE BOOM MOVEMENTS ARE
ERRATIC.
•
Toggle AUTO to start automatic mode. Observe the behavior of the
booms while correcting to the target height.
↓↓↓↓
45 AA 45
45 AA 45
45 AA 45
45 AA 45
•
The operating display shows the system is in automatic and the
target height is 45 inches.
The boom movements should be smooth and stable. Boom
corrections should stop after a few seconds, under normal conditions
(excessive wind may cause small corrections to continue).
↓↓↓↓
34 MM 36
34 MM 36
34 MM 36
34 MM 36
•
Press the MANUAL switch to return to manual mode.
If the boom corrections are done in an acceptable manner your
system is ready to use.
* Automatic System Setup Complete. *
If the corrections are not done in an acceptable manner you have three
options – (1) Retry the entire installation process; (2) Try a manual system
setup as described in Section 6.6; or (3) Call Norac for assistance.
•
If your boom does not appear to be level at the desired height
proceed to Step 9. Otherwise your system is ready to use.